High-energy micrometre-scale pixel direct conversion X-ray detector
The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition...
Ausführliche Beschreibung
Bibliographische Detailangaben
Veröffentlicht in: | Journal of synchrotron radiation. - 1994. - 28(2021), Pt 4 vom: 01. Juli, Seite 1081-1089
|
1. Verfasser: |
Scott, Christopher C
(VerfasserIn) |
Weitere Verfasser: |
Farrier, Michael,
Li, Yunzhe,
Laxer, Sam,
Ravi, Parmesh,
Kenesei, Peter,
Wojcik, Michael J,
Miceli, Antonino,
Karim, Karim S |
Format: | Online-Aufsatz
|
Sprache: | English |
Veröffentlicht: |
2021
|
Zugriff auf das übergeordnete Werk: | Journal of synchrotron radiation
|
Schlagworte: | Journal Article
amorphous selenium
high-energy X-ray detector
micrometre-scale spatial resolution |