One-dimensional parallax-free position-sensitive detector for diffraction measurements based on a home-made thin THGEM

A large parallax-free gas diffraction meter based on a thinner-THGEM (thick gaseous electron multiplier) has been developed at the Beijing Synchrotron Radiation Facility (BSRF). A thinner-THGEM of thickness 200 µm is adopted, which can be shaped into a curve to eliminate parallax-error effects. The...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 26(2019), Pt 1 vom: 01. Jan., Seite 83-88
1. Verfasser: Chen, Shi (VerfasserIn)
Weitere Verfasser: Liu, Hongbang, Liu, Qian, Zheng, Yangheng, Wang, Binglong, Huang, Wenqian, Dong, Yang, Rong, Yu, Jiao, Xinda, Guan, Yu, Wang, Jing, Li, Min, Liu, Jizhou, Zhang, Mengmeng
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2019
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article BSRF X-ray diffraction micropattern gaseous detectors thinner-THGEM
LEADER 01000naa a22002652 4500
001 NLM292832893
003 DE-627
005 20231225074005.0
007 cr uuu---uuuuu
008 231225s2019 xx |||||o 00| ||eng c
024 7 |a 10.1107/S160057751801086X  |2 doi 
028 5 2 |a pubmed24n0976.xml 
035 |a (DE-627)NLM292832893 
035 |a (NLM)30655471 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Chen, Shi  |e verfasserin  |4 aut 
245 1 0 |a One-dimensional parallax-free position-sensitive detector for diffraction measurements based on a home-made thin THGEM 
264 1 |c 2019 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 30.01.2019 
500 |a Date Revised 30.01.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A large parallax-free gas diffraction meter based on a thinner-THGEM (thick gaseous electron multiplier) has been developed at the Beijing Synchrotron Radiation Facility (BSRF). A thinner-THGEM of thickness 200 µm is adopted, which can be shaped into a curve to eliminate parallax-error effects. The detector is designed to have a 48° open angle positioned 20 cm from the powder samples. A front-end electronics board with 128 channels direct-current mode was adapted for the 8 keV BSRF beamline with 0.2 ns/100 ns stable duty cycle. Two powder samples, TiO2 and SnO2, were tested separately. The measured spectra with an angular resolution of 0.148 ± 0.081° are consistent with the data from the powder diffraction file. Combining the gas gain of the thinner-THGEM with the electronic circuit dynamic range, a very broad dynamic range of about 107 could be obtained 
650 4 |a Journal Article 
650 4 |a BSRF 
650 4 |a X-ray diffraction 
650 4 |a micropattern gaseous detectors 
650 4 |a thinner-THGEM 
700 1 |a Liu, Hongbang  |e verfasserin  |4 aut 
700 1 |a Liu, Qian  |e verfasserin  |4 aut 
700 1 |a Zheng, Yangheng  |e verfasserin  |4 aut 
700 1 |a Wang, Binglong  |e verfasserin  |4 aut 
700 1 |a Huang, Wenqian  |e verfasserin  |4 aut 
700 1 |a Dong, Yang  |e verfasserin  |4 aut 
700 1 |a Rong, Yu  |e verfasserin  |4 aut 
700 1 |a Jiao, Xinda  |e verfasserin  |4 aut 
700 1 |a Guan, Yu  |e verfasserin  |4 aut 
700 1 |a Wang, Jing  |e verfasserin  |4 aut 
700 1 |a Li, Min  |e verfasserin  |4 aut 
700 1 |a Liu, Jizhou  |e verfasserin  |4 aut 
700 1 |a Zhang, Mengmeng  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 26(2019), Pt 1 vom: 01. Jan., Seite 83-88  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:26  |g year:2019  |g number:Pt 1  |g day:01  |g month:01  |g pages:83-88 
856 4 0 |u http://dx.doi.org/10.1107/S160057751801086X  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 26  |j 2019  |e Pt 1  |b 01  |c 01  |h 83-88