X-ray grating interferometer for in situ and at-wavelength wavefront metrology

A wavefront metrology setup based on the X-ray grating interferometry technique for spatially resolved, quantitative, in situ and at-wavelength measurements of the wavefront at synchrotron radiation and hard X-ray free-electron laser beamlines is reported. Indeed, the ever-increasing demands on the...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 24(2017), Pt 1 vom: 01. Jan., Seite 150-162
1. Verfasser: Kayser, Yves (VerfasserIn)
Weitere Verfasser: David, Christian, Flechsig, Uwe, Krempasky, Juraj, Schlott, Volker, Abela, Rafael
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2017
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article X-ray grating interferometry X-ray optics XFELs wavefront metrology
LEADER 01000naa a22002652 4500
001 NLM26742082X
003 DE-627
005 20231224220638.0
007 cr uuu---uuuuu
008 231224s2017 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577516017562  |2 doi 
028 5 2 |a pubmed24n0891.xml 
035 |a (DE-627)NLM26742082X 
035 |a (NLM)28009554 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kayser, Yves  |e verfasserin  |4 aut 
245 1 0 |a X-ray grating interferometer for in situ and at-wavelength wavefront metrology 
264 1 |c 2017 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 11.07.2017 
500 |a Date Revised 13.07.2017 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A wavefront metrology setup based on the X-ray grating interferometry technique for spatially resolved, quantitative, in situ and at-wavelength measurements of the wavefront at synchrotron radiation and hard X-ray free-electron laser beamlines is reported. Indeed, the ever-increasing demands on the optical components to preserve the wavefront shape and the coherence of the delivered X-ray beam call for more and more sensitive diagnostic instruments. Thanks to its angular sensitivity, X-ray grating interferometry has been established in recent years as an adequate wavefront-sensing technique for quantitatively assessing the quality of the X-ray wavefront under working conditions and hence for the in situ investigation of X-ray optical elements. In order to characterize the optical elements at any given beamline by measuring the aberrations introduced in the wavefront, a transportable X-ray grating interferometry setup was realised at the Swiss Light Source (SLS). The instrument, which is expected to be a valuable tool for investigating the quality of the X-ray beam delivered at an endstation, will be described hereafter in terms of the hardware setup and the related data analysis procedure. Several exemplary experiments performed at the X05DA Optics beamline of the SLS will be presented 
650 4 |a Journal Article 
650 4 |a X-ray grating interferometry 
650 4 |a X-ray optics 
650 4 |a XFELs 
650 4 |a wavefront metrology 
700 1 |a David, Christian  |e verfasserin  |4 aut 
700 1 |a Flechsig, Uwe  |e verfasserin  |4 aut 
700 1 |a Krempasky, Juraj  |e verfasserin  |4 aut 
700 1 |a Schlott, Volker  |e verfasserin  |4 aut 
700 1 |a Abela, Rafael  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 24(2017), Pt 1 vom: 01. Jan., Seite 150-162  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:24  |g year:2017  |g number:Pt 1  |g day:01  |g month:01  |g pages:150-162 
856 4 0 |u http://dx.doi.org/10.1107/S1600577516017562  |3 Volltext 