Coupled rolling circle amplification loop-mediated amplification for rapid detection of short DNA sequences

Circularizable oligonucleotide probes can detect short DNA sequences with single-base resolution at the site of ligation and can be amplified by rolling circle amplification (RCA) using strand displacing polymerases. A secondary amplification scheme was developed that uses the loop-mediated amplific...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:BioTechniques. - 1988. - 45(2008), 3 vom: 01. Sept., Seite 275-80
1. Verfasser: Marciniak, Jennifer (VerfasserIn)
Weitere Verfasser: Kummel, Andrew, Esener, Sadik, Heller, Michael, Messmer, Bradley
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2008
Zugriff auf das übergeordnete Werk:BioTechniques
Schlagworte:Journal Article Research Support, N.I.H., Extramural DNA Probes DNA, Circular DNA, Single-Stranded Oligonucleotide Probes DNA Ligases EC 6.5.1.-
LEADER 01000naa a22002652 4500
001 NLM182300099
003 DE-627
005 20231223162645.0
007 cr uuu---uuuuu
008 231223s2008 xx |||||o 00| ||eng c
024 7 |a 10.2144/000112910  |2 doi 
028 5 2 |a pubmed24n0608.xml 
035 |a (DE-627)NLM182300099 
035 |a (NLM)18778251 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Marciniak, Jennifer  |e verfasserin  |4 aut 
245 1 0 |a Coupled rolling circle amplification loop-mediated amplification for rapid detection of short DNA sequences 
264 1 |c 2008 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 14.11.2008 
500 |a Date Revised 09.09.2008 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Circularizable oligonucleotide probes can detect short DNA sequences with single-base resolution at the site of ligation and can be amplified by rolling circle amplification (RCA) using strand displacing polymerases. A secondary amplification scheme was developed that uses the loop-mediated amplification reaction concurrent with RCA to achieve rapid signal development from the starting circular molecules. This isothermal reaction was found to be significantly faster than the comparable hyperbranching amplification method and could detect 100 circular copies in less than 1 h 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 7 |a DNA Probes  |2 NLM 
650 7 |a DNA, Circular  |2 NLM 
650 7 |a DNA, Single-Stranded  |2 NLM 
650 7 |a Oligonucleotide Probes  |2 NLM 
650 7 |a DNA Ligases  |2 NLM 
650 7 |a EC 6.5.1.-  |2 NLM 
700 1 |a Kummel, Andrew  |e verfasserin  |4 aut 
700 1 |a Esener, Sadik  |e verfasserin  |4 aut 
700 1 |a Heller, Michael  |e verfasserin  |4 aut 
700 1 |a Messmer, Bradley  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t BioTechniques  |d 1988  |g 45(2008), 3 vom: 01. Sept., Seite 275-80  |w (DE-627)NLM012627046  |x 1940-9818  |7 nnns 
773 1 8 |g volume:45  |g year:2008  |g number:3  |g day:01  |g month:09  |g pages:275-80 
856 4 0 |u http://dx.doi.org/10.2144/000112910  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_21 
912 |a GBV_ILN_22 
912 |a GBV_ILN_39 
912 |a GBV_ILN_40 
912 |a GBV_ILN_50 
912 |a GBV_ILN_60 
912 |a GBV_ILN_62 
912 |a GBV_ILN_65 
912 |a GBV_ILN_70 
912 |a GBV_ILN_99 
912 |a GBV_ILN_121 
912 |a GBV_ILN_130 
912 |a GBV_ILN_227 
912 |a GBV_ILN_350 
912 |a GBV_ILN_618 
912 |a GBV_ILN_640 
912 |a GBV_ILN_754 
912 |a GBV_ILN_2001 
912 |a GBV_ILN_2002 
912 |a GBV_ILN_2003 
912 |a GBV_ILN_2005 
912 |a GBV_ILN_2006 
912 |a GBV_ILN_2007 
912 |a GBV_ILN_2008 
912 |a GBV_ILN_2009 
912 |a GBV_ILN_2010 
912 |a GBV_ILN_2012 
912 |a GBV_ILN_2015 
912 |a GBV_ILN_2018 
912 |a GBV_ILN_2023 
912 |a GBV_ILN_2035 
912 |a GBV_ILN_2040 
912 |a GBV_ILN_2060 
912 |a GBV_ILN_2099 
912 |a GBV_ILN_2105 
912 |a GBV_ILN_2121 
912 |a GBV_ILN_2470 
951 |a AR 
952 |d 45  |j 2008  |e 3  |b 01  |c 09  |h 275-80