Electrostatic transducers for micromechanical resonators : free space and solid dielectric

Three electrostatic transduction methods are analyzed for a micromechanical, longitudinal mode, beam resonator. The conventional parallel plate transducer placed at the location of maximum displacement is compared to two solid, dielectric transducers internal to the resonator. Although the solid die...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 53(2006), 12 vom: 11. Dez., Seite 2484-9
1. Verfasser: Kaajakari, Ville (VerfasserIn)
Weitere Verfasser: Alastalo, Ari T, Mattila, Tomi
Format: Aufsatz
Sprache:English
Veröffentlicht: 2006
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Evaluation Study Letter
LEADER 01000naa a22002652 4500
001 NLM167359401
003 DE-627
005 20231223112749.0
007 tu
008 231223s2006 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0558.xml 
035 |a (DE-627)NLM167359401 
035 |a (NLM)17186931 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kaajakari, Ville  |e verfasserin  |4 aut 
245 1 0 |a Electrostatic transducers for micromechanical resonators  |b free space and solid dielectric 
264 1 |c 2006 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 30.01.2007 
500 |a Date Revised 10.12.2019 
500 |a published: Print 
500 |a CommentIn: IEEE Trans Ultrason Ferroelectr Freq Control. 2007 Dec;54(12):2696-8. - PMID 18276576 
500 |a Citation Status MEDLINE 
520 |a Three electrostatic transduction methods are analyzed for a micromechanical, longitudinal mode, beam resonator. The conventional parallel plate transducer placed at the location of maximum displacement is compared to two solid, dielectric transducers internal to the resonator. Although the solid dielectric offers higher permittivity than the free-space-filled transducers, the unfavorable locations of the internal transducers reduce or even remove the performance advantage of the higher permittivity 
650 4 |a Evaluation Study 
650 4 |a Letter 
700 1 |a Alastalo, Ari T  |e verfasserin  |4 aut 
700 1 |a Mattila, Tomi  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 53(2006), 12 vom: 11. Dez., Seite 2484-9  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:53  |g year:2006  |g number:12  |g day:11  |g month:12  |g pages:2484-9 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 53  |j 2006  |e 12  |b 11  |c 12  |h 2484-9