Rapid and sensitive XAFS using a tunable X-ray undulator at BL10XU of SPring-8

The design and performance of the high-brilliance XAFS facility at BL10XU of SPring-8, aimed at rapid and sensitive measurement of X-ray absorption fine structure (XAFS), is reported. Both undulator gap and double-crystal monochromator have been successfully controlled covering a wide energy range (...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 7(2000), Pt 2 vom: 01. März, Seite 89-94
1. Verfasser: Oyanagi, H (VerfasserIn)
Weitere Verfasser: Ishii, M, Lee, C H, Saini, N L, Kuwahara, Y, Saito, A, Izumi, Y, Hashimoto, H
Format: Aufsatz
Sprache:English
Veröffentlicht: 2000
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM161957307
003 DE-627
005 20250207061644.0
007 tu
008 231223s2000 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0540.xml 
035 |a (DE-627)NLM161957307 
035 |a (NLM)16609179 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Oyanagi, H  |e verfasserin  |4 aut 
245 1 0 |a Rapid and sensitive XAFS using a tunable X-ray undulator at BL10XU of SPring-8 
264 1 |c 2000 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 16.05.2006 
500 |a Date Revised 12.04.2006 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The design and performance of the high-brilliance XAFS facility at BL10XU of SPring-8, aimed at rapid and sensitive measurement of X-ray absorption fine structure (XAFS), is reported. Both undulator gap and double-crystal monochromator have been successfully controlled covering a wide energy range (5-30 keV). A versatile goniometer system, consisting of two independent high-precision goniometers, is capable of polarized XAFS in fluorescence mode and surface-sensitive experiments using a grazing-incidence geometry. By sharing major components, i.e. a monolithic Ge 100-pixel array detector and a closed-cycle He cryostat, both polarized XAFS and X-ray standing wave (XSW) experiments can be performed at low temperature (15-300 K). The performance of the spectrometer has been evaluated by recording XAFS spectra in transmission mode 
650 4 |a Journal Article 
700 1 |a Ishii, M  |e verfasserin  |4 aut 
700 1 |a Lee, C H  |e verfasserin  |4 aut 
700 1 |a Saini, N L  |e verfasserin  |4 aut 
700 1 |a Kuwahara, Y  |e verfasserin  |4 aut 
700 1 |a Saito, A  |e verfasserin  |4 aut 
700 1 |a Izumi, Y  |e verfasserin  |4 aut 
700 1 |a Hashimoto, H  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 7(2000), Pt 2 vom: 01. März, Seite 89-94  |w (DE-627)NLM09824129X  |x 0909-0495  |7 nnns 
773 1 8 |g volume:7  |g year:2000  |g number:Pt 2  |g day:01  |g month:03  |g pages:89-94 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 7  |j 2000  |e Pt 2  |b 01  |c 03  |h 89-94