Ultrasensitive Detection of Chemokines in Clinical Samples with Graphene-Based Field-Effect Transistors

© 2024 The Author(s). Advanced Materials published by Wiley‐VCH GmbH.

Bibliographische Detailangaben
Veröffentlicht in:Advanced materials (Deerfield Beach, Fla.). - 1998. - (2024) vom: 20. Nov., Seite e2407487
1. Verfasser: Kaiser, David (VerfasserIn)
Weitere Verfasser: Meyerbroeker, Nikolaus, Purschke, Werner, Sell, Simone, Neumann, Christof, Winter, Andreas, Tang, Zian, Hüger, Daniel, Maasch, Christian, Bethge, Lucas, Weimann, Thomas, Ferwerda, Gerben, de Jonge, Marien I, Schnieders, Albert, Vater, Axel, Turchanin, Andrey
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Advanced materials (Deerfield Beach, Fla.)
Schlagworte:Journal Article biosensors carbon nanomembranes graphene solution‐gated field‐effect transistors van der Waals heterostructures
LEADER 01000naa a22002652 4500
001 NLM380510995
003 DE-627
005 20241120233411.0
007 cr uuu---uuuuu
008 241120s2024 xx |||||o 00| ||eng c
024 7 |a 10.1002/adma.202407487  |2 doi 
028 5 2 |a pubmed24n1607.xml 
035 |a (DE-627)NLM380510995 
035 |a (NLM)39564692 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kaiser, David  |e verfasserin  |4 aut 
245 1 0 |a Ultrasensitive Detection of Chemokines in Clinical Samples with Graphene-Based Field-Effect Transistors 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.11.2024 
500 |a published: Print-Electronic 
500 |a Citation Status Publisher 
520 |a © 2024 The Author(s). Advanced Materials published by Wiley‐VCH GmbH. 
520 |a Due to their ultra-high sensitivity, solution-gated graphene-based field-effect transistors (SG-GFET) have been proposed for applications in bio-sensing. However, challenges regarding the functionalization of GFETs have prevented their applications in clinical diagnostics so far. Here GFET sensors based on van der Waals (vdW) heterostructures of single-layer graphene layered with a molecular ≈1 nm thick carbon nanomembrane (CNM) are presented. The CNM acts as an ultrathin molecular interposer between the graphene channel and the analyte and allows bio-functionalization without impairing the graphene properties including its charge carrier mobility. To achieve specificity and reliability in the detection of biomarkers in real patient samples, the functionalization incorporates biostable aptamers in the non-natural l-configuration and hydrophilic polyethylene glycol for avoiding non-specific adsorption. A rapid (≈5 min) detection of the clinically relevant inflammatory mediator CXCL8/IL-8 within the concentration range of 0.5 - 500 pM (5 - 5000 pg ml-1) is demonstrated in nasal swab samples collected from patients with respiratory tract infections. This detection range may aid in diagnostics of early-stage infectious diseases making the reported approach promising for the development of future medical tools 
650 4 |a Journal Article 
650 4 |a biosensors 
650 4 |a carbon nanomembranes 
650 4 |a graphene 
650 4 |a solution‐gated field‐effect transistors 
650 4 |a van der Waals heterostructures 
700 1 |a Meyerbroeker, Nikolaus  |e verfasserin  |4 aut 
700 1 |a Purschke, Werner  |e verfasserin  |4 aut 
700 1 |a Sell, Simone  |e verfasserin  |4 aut 
700 1 |a Neumann, Christof  |e verfasserin  |4 aut 
700 1 |a Winter, Andreas  |e verfasserin  |4 aut 
700 1 |a Tang, Zian  |e verfasserin  |4 aut 
700 1 |a Hüger, Daniel  |e verfasserin  |4 aut 
700 1 |a Maasch, Christian  |e verfasserin  |4 aut 
700 1 |a Bethge, Lucas  |e verfasserin  |4 aut 
700 1 |a Weimann, Thomas  |e verfasserin  |4 aut 
700 1 |a Ferwerda, Gerben  |e verfasserin  |4 aut 
700 1 |a de Jonge, Marien I  |e verfasserin  |4 aut 
700 1 |a Schnieders, Albert  |e verfasserin  |4 aut 
700 1 |a Vater, Axel  |e verfasserin  |4 aut 
700 1 |a Turchanin, Andrey  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Advanced materials (Deerfield Beach, Fla.)  |d 1998  |g (2024) vom: 20. Nov., Seite e2407487  |w (DE-627)NLM098206397  |x 1521-4095  |7 nnns 
773 1 8 |g year:2024  |g day:20  |g month:11  |g pages:e2407487 
856 4 0 |u http://dx.doi.org/10.1002/adma.202407487  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |j 2024  |b 20  |c 11  |h e2407487