Flexible PZT-based Row-Column Addressed 2D PMUT Array

This paper reports a 30×12 row-column (RC) addressed flexible piezoelectric micromachined ultrasound transducer (PMUT) array with a top-down fabrication process. The fabrication uses a temporary carrier wafer from which the array device is released by deep reactive ion etching (DRIE). About 0.8 μm t...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - PP(2024) vom: 23. Sept.
1. Verfasser: Joshi, Sanjog Vilas (VerfasserIn)
Weitere Verfasser: Sadeghpour, Sina, Kraft, Michael
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM377993883
003 DE-627
005 20240924233248.0
007 cr uuu---uuuuu
008 240924s2024 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2024.3465589  |2 doi 
028 5 2 |a pubmed24n1547.xml 
035 |a (DE-627)NLM377993883 
035 |a (NLM)39312430 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Joshi, Sanjog Vilas  |e verfasserin  |4 aut 
245 1 0 |a Flexible PZT-based Row-Column Addressed 2D PMUT Array 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 23.09.2024 
500 |a published: Print-Electronic 
500 |a Citation Status Publisher 
520 |a This paper reports a 30×12 row-column (RC) addressed flexible piezoelectric micromachined ultrasound transducer (PMUT) array with a top-down fabrication process. The fabrication uses a temporary carrier wafer from which the array device is released by deep reactive ion etching (DRIE). About 0.8 μm thick sol-gel processed Lead Zirconate Titanate (PZT) thin film acts as the active piezoelectric. The flexible PMUT membrane includes the PZT film and a 14 μm polyimide as a passive layer. A sidewall made of polyimide measuring 21 μm in thickness with a cavity of 100 μm in diameter, is realized by reactive ion etching (RIE). Laser Doppler Vibrometer (LDV) characterization of the PMUT indicates 2.7 megahertz (MHz) and 2.1 MHz as the resonance frequency in-air and underwater, respectively. Excitation of a single PMUT element coupled with 5 V direct current (DC) bias results in 1.2 nm/V sensitivity in-air whereas when the same is excited along with 10 V DC bias, a pressure response of 40 Pa/V at 1 cm is measured underwater using a hydrophone. The presented results under bending to an 8 mm bending radius show the potential for wearable applications in shallow-depth regions subject to further optimization 
650 4 |a Journal Article 
700 1 |a Sadeghpour, Sina  |e verfasserin  |4 aut 
700 1 |a Kraft, Michael  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g PP(2024) vom: 23. Sept.  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:PP  |g year:2024  |g day:23  |g month:09 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2024.3465589  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d PP  |j 2024  |b 23  |c 09