|
|
|
|
LEADER |
01000caa a22002652 4500 |
001 |
NLM377810894 |
003 |
DE-627 |
005 |
20240925232928.0 |
007 |
cr uuu---uuuuu |
008 |
240919s2024 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1111/vcp.13377
|2 doi
|
028 |
5 |
2 |
|a pubmed24n1548.xml
|
035 |
|
|
|a (DE-627)NLM377810894
|
035 |
|
|
|a (NLM)39294107
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Guerlin, Maud
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Validation of the Sysmex XN-V hematology analyzer for feline specimens
|
264 |
|
1 |
|c 2024
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 24.09.2024
|
500 |
|
|
|a Date Revised 24.09.2024
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a © 2024 The Author(s). Veterinary Clinical Pathology published by Wiley Periodicals LLC on behalf of American Society for Veterinary Clinical Pathology.
|
520 |
|
|
|a BACKGROUND: The Sysmex XN-V is derived from the new Sysmex XN series of human hematology analyzers. The main changes from the previously validated XT-2000iV analyzer include an optic-fluorescent analysis for platelets and a nucleated red blood cell (NRBC) count
|
520 |
|
|
|a OBJECTIVE: We aimed to validate the Sysmex XN-V for feline blood following the American College for Veterinary Clinical Pathology and International Council for Standardization in Hematology recommendations
|
520 |
|
|
|a METHODS: Feline EDTA blood specimens were analyzed on the Sysmex XN-V to evaluate repeatability, linearity, comparison with the XT-2000iV analyzer and manual methods, stability, and to verify the previously established Sysmex XT-2000iV RIs
|
520 |
|
|
|a RESULTS: Repeatability was excellent for most variables. Visually determined linearity was excellent or good for most variables except eosinophils and platelet variables. The correlation between the XN-V and XT-2000iV analyzers was good (≥0.82) for all variables except reticulocyte indices. Correlations between the Sysmex XN-V and manual differential counts were good to excellent for most variables, acceptable for neutrophils, and fair for monocytes and NRBC. The previously established Sysmex XT-2000iV RIs can be used to interpret results from the Sysmex XN-V analyzer for most variables except red cell distribution width and reticulocyte variables. The RI for platelet variables could not be evaluated because of platelet clumps. Changes in the Sysmex XN-V measurements after storage at 4 and 24°C were similar to those described for the Sysmex XT-2000iV analyzer
|
520 |
|
|
|a CONCLUSIONS: The performance of the Sysmex XN-V analyzer was good and compared favorably with the Sysmex XT-2000iV analyzer
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Validation Study
|
650 |
|
4 |
|a blood
|
650 |
|
4 |
|a cat
|
650 |
|
4 |
|a comparison study
|
650 |
|
4 |
|a method validation
|
650 |
|
4 |
|a platelet clumping
|
700 |
1 |
|
|a Granat, Fanny
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Grebert, Margot
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Braun, Jean-Pierre
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Geffré, Anne
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Bourgès-Abella, Nathalie
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Trumel, Catherine
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Veterinary clinical pathology
|d 1975
|g 53(2024), 3 vom: 17. Sept., Seite 294-308
|w (DE-627)NLM098159984
|x 1939-165X
|7 nnns
|
773 |
1 |
8 |
|g volume:53
|g year:2024
|g number:3
|g day:17
|g month:09
|g pages:294-308
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1111/vcp.13377
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 53
|j 2024
|e 3
|b 17
|c 09
|h 294-308
|