100 1 |a Carlomagno, Ilaria  |e verfasserin  |4 aut 
245 1 0 |a Trace-element XAFS sensitivity  |b a stress test for a new XRF multi-detector 
264 1 |c 2021 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 09.11.2021 
500 |a Date Revised 04.04.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a open access. 
520 |a X-ray absorption fine-structure (XAFS) spectroscopy can assess the chemical speciation of the elements providing their coordination and oxidation state, information generally hidden to other techniques. In the case of trace elements, achieving a good quality XAFS signal poses several challenges, as it requires high photon flux, counting statistics and detector linearity. Here, a new multi-element X-ray fluorescence detector is presented, specifically designed to probe the chemical speciation of trace 3d elements down to the p.p.m. range. The potentialities of the detector are presented through a case study: the speciation of ultra-diluted elements (Fe, Mn and Cr) in geological rocks from a calcareous formation related to the dispersal processes from Ontong (Java) volcanism (mid-Cretaceous). Trace-elements speciation is crucial in evaluating the impact of geogenic and anthropogenic harmful metals on the environment, and to evaluate the risks to human health and ecosystems. These results show that the new detector is suitable for collecting spectra of 3d elements in trace amounts in a calcareous matrix. The data quality is high enough that quantitative data analysis could be performed to determine their chemical speciation 
650 4 |a Journal Article 
650 4 |a X-ray absorption spectroscopy 
650 4 |a X-ray fluorescence 
650 4 |a fluorescence detector 
650 4 |a geology 
650 7 |a Metals  |2 NLM 
650 7 |a Trace Elements  |2 NLM 
700 1 |a Antonelli, Matias  |e verfasserin  |4 aut 
700 1 |a Aquilanti, Giuliana  |e verfasserin  |4 aut 
700 1 |a Bellutti, Pierluigi  |e verfasserin  |4 aut 
700 1 |a Bertuccio, Giuseppe  |e verfasserin  |4 aut 
700 1 |a Borghi, Giacomo  |e verfasserin  |4 aut 
700 1 |a Cautero, Giuseppe  |e verfasserin  |4 aut 
700 1 |a Cirrincione, Daniela  |e verfasserin  |4 aut 
700 1 |a de Giudici, Giovanni  |e verfasserin  |4 aut 
700 1 |a Ficorella, Francesco  |e verfasserin  |4 aut 
700 1 |a Gandola, Massimo  |e verfasserin  |4 aut 
700 1 |a Giuressi, Dario  |e verfasserin  |4 aut 
700 1 |a Medas, Daniela  |e verfasserin  |4 aut 
700 1 |a Mele, Filippo  |e verfasserin  |4 aut 
700 1 |a Menk, Ralf H  |e verfasserin  |4 aut 
700 1 |a Olivi, Luca  |e verfasserin  |4 aut 
700 1 |a Orzan, Giulio  |e verfasserin  |4 aut 
700 1 |a Picciotto, Antonino  |e verfasserin  |4 aut 
700 1 |a Podda, Francesca  |e verfasserin  |4 aut 
700 1 |a Rachevski, Alexandre  |e verfasserin  |4 aut 
700 1 |a Rashevskaya, Irina  |e verfasserin  |4 aut 
700 1 |a Stebel, Luigi  |e verfasserin  |4 aut 
700 1 |a Vacchi, Andrea  |e verfasserin  |4 aut 
700 1 |a Zampa, Gianluigi  |e verfasserin  |4 aut 
700 1 |a Zampa, Nicola  |e verfasserin  |4 aut 
700 1 |a Zorzi, Nicola  |e verfasserin  |4 aut 
700 1 |a Meneghini, Carlo  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 28(2021), Pt 6 vom: 01. Nov., Seite 1811-1819  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:28  |g year:2021  |g number:Pt 6  |g day:01  |g month:11  |g pages:1811-1819 