|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM325028923 |
003 |
DE-627 |
005 |
20231225191551.0 |
007 |
cr uuu---uuuuu |
008 |
231225s2021 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1107/S1600577521001740
|2 doi
|
028 |
5 |
2 |
|a pubmed24n1083.xml
|
035 |
|
|
|a (DE-627)NLM325028923
|
035 |
|
|
|a (NLM)33950001
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Pao, Chih Wen
|e verfasserin
|4 aut
|
245 |
1 |
4 |
|a The new X-ray absorption fine-structure beamline with sub-second time resolution at the Taiwan Photon Source
|
264 |
|
1 |
|c 2021
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Revised 15.06.2021
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status PubMed-not-MEDLINE
|
520 |
|
|
|a open access.
|
520 |
|
|
|a The new TPS 44A beamline at the Taiwan Photon Source, located at the National Synchrotron Radiation Research Center, is presented. This beamline is equipped with a new quick-scanning monochromator (Q-Mono), which can provide both conventional step-by-step scans (s-scans) and on-the-fly scans (q-scans) for X-ray absorption fine-structure (XAFS) spectroscopy experiments, including X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine-structure (EXAFS) spectral measurements. Ti and Te K-edge XAFS spectra were used to demonstrate the capability of collecting spectra at the limits of the working energy range. The Ni and Cu K-edge XAFS spectra for a Cu-doped Pt/Ni nanocomposite were acquired to test the performance of the newly commissioned beamline. Pt L3- and Ru K-edge quick-scanning XAFS (QXAFS) spectra for standard Pt and Ru foils, respectively, revealed the stability of the q-scan technique. The results also demonstrated the beamline's ability to collect XAFS spectra on a sub-second timescale. Furthermore, a Zn(s)|Zn2+(aq)|Cu(s) system was tested to indicate that the states of the Zn electrode could be observed in real time for charging and discharging conditions using an in situ/operando setup combined with QXAFS measurements
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a QXAFS
|
650 |
|
4 |
|a XAFS
|
650 |
|
4 |
|a in situ/operando
|
700 |
1 |
|
|a Chen, Jeng Lung
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Lee, Jyh Fu
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Tsai, Meng Che
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Huang, Chi Yi
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Chiu, Chao Chih
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Chang, Chao Yu
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Chiang, Liang Chih
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Huang, Yu Shan
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Journal of synchrotron radiation
|d 1994
|g 28(2021), Pt 3 vom: 01. Mai, Seite 930-938
|w (DE-627)NLM09824129X
|x 1600-5775
|7 nnns
|
773 |
1 |
8 |
|g volume:28
|g year:2021
|g number:Pt 3
|g day:01
|g month:05
|g pages:930-938
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1107/S1600577521001740
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_40
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_2005
|
951 |
|
|
|a AR
|
952 |
|
|
|d 28
|j 2021
|e Pt 3
|b 01
|c 05
|h 930-938
|