On-demand correction for X-ray response non-uniformity in microstrip detectors by a data-driven approach

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 27(2020), Pt 5 vom: 01. Sept., Seite 1172-1179
1. Verfasser: Kato, Kenichi (VerfasserIn)
Weitere Verfasser: Shigeta, Kazuya
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article X-ray detectors X-ray scattering data science flat-field correction
LEADER 01000caa a22002652c 4500
001 NLM314495401
003 DE-627
005 20250227221128.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577520008929  |2 doi 
028 5 2 |a pubmed25n1048.xml 
035 |a (DE-627)NLM314495401 
035 |a (NLM)32876591 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kato, Kenichi  |e verfasserin  |4 aut 
245 1 0 |a On-demand correction for X-ray response non-uniformity in microstrip detectors by a data-driven approach 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 16.09.2020 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a A statistical approach, which was previously developed to correct scattering data for X-ray response non-uniformity (XRNU) in microstrip detectors, has been improved to significantly reduce the correcting time. The improved algorithm has succeeded in increasing the utilization rate of data acquired for reference intensity to 98%. As a result, the correcting time was reduced from half a day to half an hour, which was shorter than the typical measuring time of a sample. Moreover, the present approach was found to yield better correction results than the previous one. The data-driven approach enabled the on-demand correction for XRNU according to the detector and experimental settings. The present study will encourage the correction of scattering data for XRNU in area detectors 
650 4 |a Journal Article 
650 4 |a X-ray detectors 
650 4 |a X-ray scattering 
650 4 |a data science 
650 4 |a flat-field correction 
700 1 |a Shigeta, Kazuya  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 27(2020), Pt 5 vom: 01. Sept., Seite 1172-1179  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:27  |g year:2020  |g number:Pt 5  |g day:01  |g month:09  |g pages:1172-1179 
856 4 0 |u http://dx.doi.org/10.1107/S1600577520008929  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 27  |j 2020  |e Pt 5  |b 01  |c 09  |h 1172-1179