A five-axis parallel kinematic mirror unit for soft X-ray beamlines at MAX IV

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 27(2020), Pt 2 vom: 01. März, Seite 262-271
1. Verfasser: Agåker, Marcus (VerfasserIn)
Weitere Verfasser: Mueller, Frieder, Norsk Jensen, Brian, Åhnberg, Karl, Sjöblom, Peter, Deiwiks, Jochen, Henniger, Hans, Pärna, Rainer, Knudsen, Jan, Thiagarajan, Balasubramanian, Såthe, Conny
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article MAX IV beamline component optics kinematics soft X-ray
LEADER 01000naa a22002652 4500
001 NLM307415694
003 DE-627
005 20231225125520.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1107/S160057751901693X  |2 doi 
028 5 2 |a pubmed24n1024.xml 
035 |a (DE-627)NLM307415694 
035 |a (NLM)32153265 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Agåker, Marcus  |e verfasserin  |4 aut 
245 1 2 |a A five-axis parallel kinematic mirror unit for soft X-ray beamlines at MAX IV 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 15.03.2020 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a With the introduction of the multi-bend achromats in the new fourth-generation storage rings the emittance has decreased by an order of magnitude resulting in increased brightness. However, the higher brightness comes with smaller beam sizes and narrower radiation cones. As a consequence, the requirements on mechanical stability regarding the beamline components increases. Here an innovative five-axis parallel kinematic mirror unit for use with soft X-ray beamlines using off-axis grazing-incidence optics is presented. Using simulations and measurements from the HIPPIE beamline at the MAX IV Laboratory it is shown that it has no Eigen frequencies below 90 Hz. Its positioning accuracy is better than 25 nm linearly and 17-35 µrad angularly depending on the mirror chamber dimensions 
650 4 |a Journal Article 
650 4 |a MAX IV 
650 4 |a beamline component 
650 4 |a optics kinematics 
650 4 |a soft X-ray 
700 1 |a Mueller, Frieder  |e verfasserin  |4 aut 
700 1 |a Norsk Jensen, Brian  |e verfasserin  |4 aut 
700 1 |a Åhnberg, Karl  |e verfasserin  |4 aut 
700 1 |a Sjöblom, Peter  |e verfasserin  |4 aut 
700 1 |a Deiwiks, Jochen  |e verfasserin  |4 aut 
700 1 |a Henniger, Hans  |e verfasserin  |4 aut 
700 1 |a Pärna, Rainer  |e verfasserin  |4 aut 
700 1 |a Knudsen, Jan  |e verfasserin  |4 aut 
700 1 |a Thiagarajan, Balasubramanian  |e verfasserin  |4 aut 
700 1 |a Såthe, Conny  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 27(2020), Pt 2 vom: 01. März, Seite 262-271  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:27  |g year:2020  |g number:Pt 2  |g day:01  |g month:03  |g pages:262-271 
856 4 0 |u http://dx.doi.org/10.1107/S160057751901693X  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 27  |j 2020  |e Pt 2  |b 01  |c 03  |h 262-271