A five-axis parallel kinematic mirror unit for soft X-ray beamlines at MAX IV

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 27(2020), Pt 2 vom: 01. März, Seite 262-271
1. Verfasser: Agåker, Marcus (VerfasserIn)
Weitere Verfasser: Mueller, Frieder, Norsk Jensen, Brian, Åhnberg, Karl, Sjöblom, Peter, Deiwiks, Jochen, Henniger, Hans, Pärna, Rainer, Knudsen, Jan, Thiagarajan, Balasubramanian, Såthe, Conny
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article MAX IV beamline component optics kinematics soft X-ray
Beschreibung
Zusammenfassung:open access.
With the introduction of the multi-bend achromats in the new fourth-generation storage rings the emittance has decreased by an order of magnitude resulting in increased brightness. However, the higher brightness comes with smaller beam sizes and narrower radiation cones. As a consequence, the requirements on mechanical stability regarding the beamline components increases. Here an innovative five-axis parallel kinematic mirror unit for use with soft X-ray beamlines using off-axis grazing-incidence optics is presented. Using simulations and measurements from the HIPPIE beamline at the MAX IV Laboratory it is shown that it has no Eigen frequencies below 90 Hz. Its positioning accuracy is better than 25 nm linearly and 17-35 µrad angularly depending on the mirror chamber dimensions
Beschreibung:Date Revised 15.03.2020
published: Print-Electronic
Citation Status PubMed-not-MEDLINE
ISSN:1600-5775
DOI:10.1107/S160057751901693X