Trace and bulk organics removal during ozone-biofiltration treatment for potable reuse applications

© 2019 Water Environment Federation.

Bibliographische Detailangaben
Veröffentlicht in:Water environment research : a research publication of the Water Environment Federation. - 1998. - 92(2020), 3 vom: 30. März, Seite 430-440
1. Verfasser: Sundaram, Vijay (VerfasserIn)
Weitere Verfasser: Pagilla, Krishna
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2020
Zugriff auf das übergeordnete Werk:Water environment research : a research publication of the Water Environment Federation
Schlagworte:Journal Article advanced water treatment biofiltration biological activated carbon contaminants of emerging concern ozonation potable reuse Drinking Water Water Pollutants, Chemical Ozone 66H7ZZK23N
LEADER 01000naa a22002652 4500
001 NLM300221401
003 DE-627
005 20231225102039.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1002/wer.1202  |2 doi 
028 5 2 |a pubmed24n1000.xml 
035 |a (DE-627)NLM300221401 
035 |a (NLM)31411786 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Sundaram, Vijay  |e verfasserin  |4 aut 
245 1 0 |a Trace and bulk organics removal during ozone-biofiltration treatment for potable reuse applications 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 06.03.2020 
500 |a Date Revised 06.03.2020 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a © 2019 Water Environment Federation. 
520 |a This study investigated impact of ozone/biological activated carbon (BAC) filtration design and operational parameters on contaminants of emerging concern (CEC) and bulk organics removal over 450 days of operation. Two parallel BAC filters with identical media and influent were maintained, each at a different empty bed contact time of 10 and 20 min. This study captured the CEC removal performance of a BAC filter over an extended operational period after treating 65,000 bed volumes. Ozone system was operated at ozone dose to TOC ratio range of 0.9-2. Biofilter with lower EBCT (10 min) and exhausted media resulted in poor removals of Tris(2-chloroethyl) phosphate (TCEP), perfluorooctanoic acid (PFOA), sucralose, meprobamate, N,N-diethyl-m-toluamide (DEET), and cotinine. Biofilter with higher EBCT (20 min) and remaining adsorptive effects resulted in significant (84% or more) removal of all CECs that were detected in the ozonated effluent. Increasing both ozone dose and BAC EBCT resulted in increased removal of UV absorbance (UVA254 ). The evaluation of impact of ozone:TOC ratio and BAC EBCT on CEC removal, bulk organics (TOC), and UVA254 performed in this study confirmed the importance of these two parameters on overall success of nonreverse osmosis (RO) potable reuse projects. PRACTITIONER POINTS: Ozone-BAC biofiltration is feasible strategy for indirect potable reuse water reclamation. Ozone-BAC empty bed contact time is a critical design parameter. Adsorption and biodegradation are both important mechanisms for trace organic contaminant removal in BAC 
650 4 |a Journal Article 
650 4 |a advanced water treatment 
650 4 |a biofiltration 
650 4 |a biological activated carbon 
650 4 |a contaminants of emerging concern 
650 4 |a ozonation 
650 4 |a potable reuse 
650 7 |a Drinking Water  |2 NLM 
650 7 |a Water Pollutants, Chemical  |2 NLM 
650 7 |a Ozone  |2 NLM 
650 7 |a 66H7ZZK23N  |2 NLM 
700 1 |a Pagilla, Krishna  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water environment research : a research publication of the Water Environment Federation  |d 1998  |g 92(2020), 3 vom: 30. März, Seite 430-440  |w (DE-627)NLM098214292  |x 1554-7531  |7 nnns 
773 1 8 |g volume:92  |g year:2020  |g number:3  |g day:30  |g month:03  |g pages:430-440 
856 4 0 |u http://dx.doi.org/10.1002/wer.1202  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 92  |j 2020  |e 3  |b 30  |c 03  |h 430-440