Enhancing signal-to-noise ratio and resolution in low-field NMR relaxation measurements using post-acquisition digital filters

© 2018 John Wiley & Sons, Ltd.

Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in chemistry : MRC. - 1985. - 57(2019), 9 vom: 15. Sept., Seite 616-625
1. Verfasser: Monaretto, Tatiana (VerfasserIn)
Weitere Verfasser: Souza, Andre, Moraes, Tiago Bueno, Bertucci-Neto, Victor, Rondeau-Mouro, Corinne, Colnago, Luiz Alberto
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2019
Zugriff auf das übergeordnete Werk:Magnetic resonance in chemistry : MRC
Schlagworte:Journal Article Research Support, Non-U.S. Gov't CPMG CWFP Savitzky-Golay filter data compression low-field NMR post-acquisition filter wavelet transform
LEADER 01000naa a22002652 4500
001 NLM290761441
003 DE-627
005 20231225065421.0
007 cr uuu---uuuuu
008 231225s2019 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrc.4806  |2 doi 
028 5 2 |a pubmed24n0969.xml 
035 |a (DE-627)NLM290761441 
035 |a (NLM)30443995 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Monaretto, Tatiana  |e verfasserin  |4 aut 
245 1 0 |a Enhancing signal-to-noise ratio and resolution in low-field NMR relaxation measurements using post-acquisition digital filters 
264 1 |c 2019 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 02.10.2019 
500 |a Date Revised 08.01.2020 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a © 2018 John Wiley & Sons, Ltd. 
520 |a The traditional way to enhance signal-to-noise ratio (SNR) of nuclear magnetic resonance (NMR) signals is to increase the number of scans. However, this procedure increases the measuring time that can be prohibitive for some applications. Therefore, we have tested the use of several post-acquisition digital filters to enhance SNR up to one order of magnitude in time domain NMR (TD-NMR) relaxation measurements. The procedures were studied using continuous wave free precession (CWFP-T1 ) signals, acquired with very low flip angles that contain six times more noise than the Carr-Purcell-Meiboom-Gill (CPMG) signal of the same sample and experimental time. Linear (LI) and logarithmic (LO) data compression, low-pass infinity impulse response (LP), Savitzky-Golay (SG), and wavelet transform (WA) post-acquisition filters enhanced the SNR of the CWFP-T1 signals by at least six times. The best filters were LO, SG, and WA that have high enhancement in SNR without significant distortions in the ILT relaxation distribution data. Therefore, it was demonstrated that these post-acquisition digital filters could be a useful way to denoise CWFP-T1 , as well as CPMG noisy signals, and consequently reducing the experimental time. It was also demonstrated that filtered CWFP-T1 method has the potential to be a rapid and nondestructive method to measure fat content in beef and certainly in other meat samples 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a CPMG 
650 4 |a CWFP 
650 4 |a Savitzky-Golay filter 
650 4 |a data compression 
650 4 |a low-field NMR 
650 4 |a post-acquisition filter 
650 4 |a wavelet transform 
700 1 |a Souza, Andre  |e verfasserin  |4 aut 
700 1 |a Moraes, Tiago Bueno  |e verfasserin  |4 aut 
700 1 |a Bertucci-Neto, Victor  |e verfasserin  |4 aut 
700 1 |a Rondeau-Mouro, Corinne  |e verfasserin  |4 aut 
700 1 |a Colnago, Luiz Alberto  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in chemistry : MRC  |d 1985  |g 57(2019), 9 vom: 15. Sept., Seite 616-625  |w (DE-627)NLM098179667  |x 1097-458X  |7 nnns 
773 1 8 |g volume:57  |g year:2019  |g number:9  |g day:15  |g month:09  |g pages:616-625 
856 4 0 |u http://dx.doi.org/10.1002/mrc.4806  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 57  |j 2019  |e 9  |b 15  |c 09  |h 616-625