|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM290399807 |
003 |
DE-627 |
005 |
20231225064639.0 |
007 |
cr uuu---uuuuu |
008 |
231225s2018 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1107/S1600577518013401
|2 doi
|
028 |
5 |
2 |
|a pubmed24n0967.xml
|
035 |
|
|
|a (DE-627)NLM290399807
|
035 |
|
|
|a (NLM)30407195
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Wagner, Willi L
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Towards synchrotron phase-contrast lung imaging in patients - a proof-of-concept study on porcine lungs in a human-scale chest phantom
|
264 |
|
1 |
|c 2018
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 21.12.2018
|
500 |
|
|
|a Date Revised 21.12.2018
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a In-line free propagation phase-contrast synchrotron tomography of the lungs has been shown to provide superior image quality compared with attenuation-based computed tomography (CT) in small-animal studies. The present study was performed to prove the applicability on a human-patient scale using a chest phantom with ventilated fresh porcine lungs. Local areas of interest were imaged with a pixel size of 100 µm, yielding a high-resolution depiction of anatomical hallmarks of healthy lungs and artificial lung nodules. Details like fine spiculations into surrounding alveolar spaces were shown on a micrometre scale. Minor differences in artificial lung nodule density were detected by phase retrieval. Since we only applied a fraction of the X-ray dose used for clinical high-resolution CT scans, it is believed that this approach may become applicable to the detailed assessment of focal lung lesions in patients in the future
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a high-resolution porcine lung imaging
|
650 |
|
4 |
|a phase retrieval
|
650 |
|
4 |
|a preclinical chest phantom
|
650 |
|
4 |
|a propagation based imaging
|
650 |
|
4 |
|a synchrotron radiation
|
700 |
1 |
|
|a Wuennemann, Felix
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Pacilé, Serena
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Albers, Jonas
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Arfelli, Fulvia
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Dreossi, Diego
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Biederer, Jürgen
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Konietzke, Philip
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Stiller, Wolfram
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Wielpütz, Mark O
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Accardo, Agostino
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Confalonieri, Marco
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Cova, Maria
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Lotz, Joachim
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Alves, Frauke
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Kauczor, Hans Ulrich
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Tromba, Giuliana
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Dullin, Christian
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Journal of synchrotron radiation
|d 1994
|g 25(2018), Pt 6 vom: 01. Nov., Seite 1827-1832
|w (DE-627)NLM09824129X
|x 1600-5775
|7 nnns
|
773 |
1 |
8 |
|g volume:25
|g year:2018
|g number:Pt 6
|g day:01
|g month:11
|g pages:1827-1832
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1107/S1600577518013401
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_40
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_2005
|
951 |
|
|
|a AR
|
952 |
|
|
|d 25
|j 2018
|e Pt 6
|b 01
|c 11
|h 1827-1832
|