Flow cytometric assessment of leukocyte kinetics for the monitoring of tissue damage

Copyright © 2018. Published by Elsevier Inc.

Bibliographische Detailangaben
Veröffentlicht in:Clinical immunology (Orlando, Fla.). - 1999. - 197(2018) vom: 15. Dez., Seite 224-230
1. Verfasser: van den Bossche, Wouter B L (VerfasserIn)
Weitere Verfasser: Rykov, Kyrill, Teodosio, Cristina, Ten Have, Bas L E F, Knobben, Bas A S, Sietsma, Maurits S, Josiassen, Karin, de Bruin-Versteeg, Sandra, Orfao, Alberto, van Dongen, Jacques J M, van Raay, Jos J A M
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Clinical immunology (Orlando, Fla.)
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Flow cytometry and multiparameter analysis Immune monitoring Leukocytes Tissue damage
LEADER 01000naa a22002652 4500
001 NLM289255880
003 DE-627
005 20231225062143.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.clim.2018.09.014  |2 doi 
028 5 2 |a pubmed24n0964.xml 
035 |a (DE-627)NLM289255880 
035 |a (NLM)30290225 
035 |a (PII)S1521-6616(18)30120-7 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a van den Bossche, Wouter B L  |e verfasserin  |4 aut 
245 1 0 |a Flow cytometric assessment of leukocyte kinetics for the monitoring of tissue damage 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 07.10.2019 
500 |a Date Revised 07.10.2019 
500 |a published: Print-Electronic 
500 |a ErratumIn: Clin Immunol. 2020 Apr;213:108344. - PMID 31964597 
500 |a Citation Status MEDLINE 
520 |a Copyright © 2018. Published by Elsevier Inc. 
520 |a Leukocyte populations quickly respond to tissue damage, but most leukocyte kinetic studies are not based on multiparameter flow cytometry. We systematically investigated several blood leukocyte populations after controlled tissue damage. 48 patients were assigned to either an anterior or posterolateral total hip arthroplasty. Peripheral blood was collected pre-operatively and at 2 h, 24 h, 48 h, 2 and 6 weeks postoperatively and assessed by flow cytometry for absolute counts of multiple leukocyte populations using standardized EuroFlow protocols. Absolute counts of leukocyte subsets differed significantly between consecutive time points. Neutrophils increased instantly after surgery, while most leukocyte subsets initially decreased, followed by increasing cell counts until 48 h. At two weeks all leukocyte counts were restored to pre-operative counts. Immune cell kinetics upon acute tissue damage exhibit reproducible patterns, which differ between the leukocyte subsets and with "opposite kinetics" among monocyte subsets. Flow cytometric leukocyte monitoring can be used to minimally invasively monitor tissue damage 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a Flow cytometry and multiparameter analysis 
650 4 |a Immune monitoring 
650 4 |a Leukocytes 
650 4 |a Tissue damage 
700 1 |a Rykov, Kyrill  |e verfasserin  |4 aut 
700 1 |a Teodosio, Cristina  |e verfasserin  |4 aut 
700 1 |a Ten Have, Bas L E F  |e verfasserin  |4 aut 
700 1 |a Knobben, Bas A S  |e verfasserin  |4 aut 
700 1 |a Sietsma, Maurits S  |e verfasserin  |4 aut 
700 1 |a Josiassen, Karin  |e verfasserin  |4 aut 
700 1 |a de Bruin-Versteeg, Sandra  |e verfasserin  |4 aut 
700 1 |a Orfao, Alberto  |e verfasserin  |4 aut 
700 1 |a van Dongen, Jacques J M  |e verfasserin  |4 aut 
700 1 |a van Raay, Jos J A M  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Clinical immunology (Orlando, Fla.)  |d 1999  |g 197(2018) vom: 15. Dez., Seite 224-230  |w (DE-627)NLM098196855  |x 1521-7035  |7 nnns 
773 1 8 |g volume:197  |g year:2018  |g day:15  |g month:12  |g pages:224-230 
856 4 0 |u http://dx.doi.org/10.1016/j.clim.2018.09.014  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_11 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 197  |j 2018  |b 15  |c 12  |h 224-230