Pulse-resolved intensity measurements at a hard X-ray FEL using semi-transparent diamond detectors

Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 25(2018), Pt 1 vom: 01. Jan., Seite 177-188
1. Verfasser: Roth, Thomas (VerfasserIn)
Weitere Verfasser: Freund, Wolfgang, Boesenberg, Ulrike, Carini, Gabriella, Song, Sanghoon, Lefeuvre, Gwenaëlle, Goikhman, Alexander, Fischer, Martin, Schreck, Matthias, Grünert, Jan, Madsen, Anders
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2018
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article X-ray intensity measurement XFEL diamond detector
LEADER 01000caa a22002652 4500
001 NLM279354363
003 DE-627
005 20250222200847.0
007 cr uuu---uuuuu
008 231225s2018 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577517015016  |2 doi 
028 5 2 |a pubmed25n0931.xml 
035 |a (DE-627)NLM279354363 
035 |a (NLM)29271767 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Roth, Thomas  |e verfasserin  |4 aut 
245 1 0 |a Pulse-resolved intensity measurements at a hard X-ray FEL using semi-transparent diamond detectors 
264 1 |c 2018 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.11.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in the beam. FELs are characterized by strong pulse-to-pulse intensity fluctuations due to the self-amplified spontaneous emission (SASE) process and in many experiments it is mandatory to monitor the intensity of each individual pulse. Two diamond detectors with different electrode materials, beryllium and graphite, were tested as intensity monitors at the XCS endstation of the Linac Coherent Light Source (LCLS) using the pink SASE beam at 9 keV. The performance is compared with LCLS standard monitors that detect X-rays backscattered from thin SiN foils placed in the beam. The graphite detector can also be used as a beam position monitor although with rather coarse resolution 
650 4 |a Journal Article 
650 4 |a X-ray intensity measurement 
650 4 |a XFEL 
650 4 |a diamond detector 
700 1 |a Freund, Wolfgang  |e verfasserin  |4 aut 
700 1 |a Boesenberg, Ulrike  |e verfasserin  |4 aut 
700 1 |a Carini, Gabriella  |e verfasserin  |4 aut 
700 1 |a Song, Sanghoon  |e verfasserin  |4 aut 
700 1 |a Lefeuvre, Gwenaëlle  |e verfasserin  |4 aut 
700 1 |a Goikhman, Alexander  |e verfasserin  |4 aut 
700 1 |a Fischer, Martin  |e verfasserin  |4 aut 
700 1 |a Schreck, Matthias  |e verfasserin  |4 aut 
700 1 |a Grünert, Jan  |e verfasserin  |4 aut 
700 1 |a Madsen, Anders  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 25(2018), Pt 1 vom: 01. Jan., Seite 177-188  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:25  |g year:2018  |g number:Pt 1  |g day:01  |g month:01  |g pages:177-188 
856 4 0 |u http://dx.doi.org/10.1107/S1600577517015016  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 25  |j 2018  |e Pt 1  |b 01  |c 01  |h 177-188