Accuracy of stress measurement by Laue microdiffraction (Laue-DIC method) : the influence of image noise, calibration errors and spot number

Laue microdiffraction, available at several synchrotron radiation facilities, is well suited for measuring the intragranular stress field in deformed materials thanks to the achievable submicrometer beam size. The traditional method for extracting elastic strain (and hence stress) and lattice orient...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 24(2017), Pt 4 vom: 01. Juli, Seite 802-817
1. Verfasser: Zhang, F G (VerfasserIn)
Weitere Verfasser: Bornert, M, Petit, J, Castelnau, O
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2017
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Laue microdiffraction digital image correlation image noise stress analysis
LEADER 01000naa a22002652 4500
001 NLM273421689
003 DE-627
005 20231225001208.0
007 cr uuu---uuuuu
008 231225s2017 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577517006622  |2 doi 
028 5 2 |a pubmed24n0911.xml 
035 |a (DE-627)NLM273421689 
035 |a (NLM)28664888 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Zhang, F G  |e verfasserin  |4 aut 
245 1 0 |a Accuracy of stress measurement by Laue microdiffraction (Laue-DIC method)  |b the influence of image noise, calibration errors and spot number 
264 1 |c 2017 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.11.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Laue microdiffraction, available at several synchrotron radiation facilities, is well suited for measuring the intragranular stress field in deformed materials thanks to the achievable submicrometer beam size. The traditional method for extracting elastic strain (and hence stress) and lattice orientation from a microdiffraction image relies on fitting each Laue spot with an analytical function to estimate the peak position on the detector screen. The method is thus limited to spots exhibiting ellipsoidal shapes, thereby impeding the study of specimens plastically deformed. To overcome this difficulty, the so-called Laue-DIC method introduces digital image correlation (DIC) for the evaluation of the relative positions of spots, which can thus be of any shape. This paper is dedicated to evaluating the accuracy of this Laue-DIC method. First, a simple image noise model is established and verified on the data acquired at beamline BM32 of the European Synchrotron Radiation Facility. Then, the effect of image noise on errors on spot displacement measured by DIC is evaluated by Monte Carlo simulation. Finally, the combined effect of the image noise, calibration errors and the number of Laue spots used for data treatment is investigated. Results in terms of the uncertainty of stress measurement are provided, and various error regimes are identified 
650 4 |a Journal Article 
650 4 |a Laue microdiffraction 
650 4 |a digital image correlation 
650 4 |a image noise 
650 4 |a stress analysis 
700 1 |a Bornert, M  |e verfasserin  |4 aut 
700 1 |a Petit, J  |e verfasserin  |4 aut 
700 1 |a Castelnau, O  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 24(2017), Pt 4 vom: 01. Juli, Seite 802-817  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:24  |g year:2017  |g number:Pt 4  |g day:01  |g month:07  |g pages:802-817 
856 4 0 |u http://dx.doi.org/10.1107/S1600577517006622  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 24  |j 2017  |e Pt 4  |b 01  |c 07  |h 802-817