Analytic and quality control validation and assessment of field performance of a point-of-care chemistry analyzer for use in the White rhinoceros

© 2017 American Society for Veterinary Clinical Pathology.

Bibliographische Detailangaben
Veröffentlicht in:Veterinary clinical pathology. - 1975. - 46(2017), 1 vom: 02. März, Seite 100-110
1. Verfasser: Hooijberg, Emma H (VerfasserIn)
Weitere Verfasser: Steenkamp, Gerhard, du Preez, Jacques P, Goddard, Amelia
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2017
Zugriff auf das übergeordnete Werk:Veterinary clinical pathology
Schlagworte:Journal Article Validation Study Ceratotherium simum VetTest dry chemistry total allowable error wildlife
LEADER 01000caa a22002652c 4500
001 NLM268584311
003 DE-627
005 20250221052615.0
007 cr uuu---uuuuu
008 231224s2017 xx |||||o 00| ||eng c
024 7 |a 10.1111/vcp.12456  |2 doi 
028 5 2 |a pubmed25n0895.xml 
035 |a (DE-627)NLM268584311 
035 |a (NLM)28152184 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Hooijberg, Emma H  |e verfasserin  |4 aut 
245 1 0 |a Analytic and quality control validation and assessment of field performance of a point-of-care chemistry analyzer for use in the White rhinoceros 
264 1 |c 2017 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 26.09.2017 
500 |a Date Revised 10.12.2019 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a © 2017 American Society for Veterinary Clinical Pathology. 
520 |a BACKGROUND: A chemistry point-of-care analyzer would be useful for evaluating injured wildlife, particularly White rhinoceros (Ceratotherium simum) that survive poaching attempts. The IDEXX VetTest could be suitable, but species-specific validation, development of a statistical quality control (QC) strategy, and evaluation under field conditions are necessary 
520 |a OBJECTIVES: The objectives were to (1) validate the VetTest for the White rhinoceros, (2) perform QC validation on the VetTest and generate a statistical QC strategy, and (3) apply this QC strategy to monitor performance under typical field conditions 
520 |a METHODS: Differences between White rhinoceros heparin plasma and serum, short-term imprecision, and reportable range using rhinoceros plasma and long-term imprecision using commercial quality control material (QCM) were assessed against prescribed total allowable error (TEa ) for up to 15 analytes. Quality control validation was performed using data from the long-term imprecision study and TEa . A QC strategy using QCM was developed and used to monitor performance under field conditions 
520 |a RESULTS: Imprecision was acceptable for all analytes except for ALP, ALT, and AST at low activities. The reportable range for AST and LDH differed from the manufacturer's specifications. Eleven analytes were suitable for statistical QC using the 13s rule, 3 using the 2s rule; ALP was not suitable. In the field, observed error was < TEa for all 15 analytes and the sigma metric was > 3.0 for 12 analytes 
520 |a CONCLUSIONS: The VetTest is suitable for use in the White rhinoceros. Statistical QC is possible for most analytes and useful for evaluation of field performance 
650 4 |a Journal Article 
650 4 |a Validation Study 
650 4 |a Ceratotherium simum 
650 4 |a VetTest 
650 4 |a dry chemistry 
650 4 |a total allowable error 
650 4 |a wildlife 
700 1 |a Steenkamp, Gerhard  |e verfasserin  |4 aut 
700 1 |a du Preez, Jacques P  |e verfasserin  |4 aut 
700 1 |a Goddard, Amelia  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Veterinary clinical pathology  |d 1975  |g 46(2017), 1 vom: 02. März, Seite 100-110  |w (DE-627)NLM098159984  |x 1939-165X  |7 nnas 
773 1 8 |g volume:46  |g year:2017  |g number:1  |g day:02  |g month:03  |g pages:100-110 
856 4 0 |u http://dx.doi.org/10.1111/vcp.12456  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 