|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM23680300X |
003 |
DE-627 |
005 |
20231224110328.0 |
007 |
cr uuu---uuuuu |
008 |
231224s2014 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1021/la4049852
|2 doi
|
028 |
5 |
2 |
|a pubmed24n0789.xml
|
035 |
|
|
|a (DE-627)NLM23680300X
|
035 |
|
|
|a (NLM)24673363
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Ali, Md Azahar
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Lipid-lipid interactions in aminated reduced graphene oxide interface for biosensing application
|
264 |
|
1 |
|c 2014
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 10.04.2015
|
500 |
|
|
|a Date Revised 15.04.2014
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a A label-free biosensor based on antiapolipoprotein B 100 functionalized-aminated reduced graphene oxide interface has been fabricated for detection of low density lipoprotein (LDL or lipid) cholesterol. The aminated reduced graphene oxide (NH2-rGO) based electrode surface is covalently functionalized with antiapolipoprotein B 100 (AAB or lipid) using EDC/NHS coupling chemistry. The lipid-lipid interactions at the NH2-rGO electrode surface have been investigated using electrochemical impedance spectroscopic technique. The structural and morphological investigations of NH2-rGO based immunosensor have been accomplished via transmission electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, UV-visible, and electrochemical techniques. The impedimetric response of the proposed immunosensor shows excellent sensitivity (612 Ω mg(-1) dL cm(-2)), a response time of 250 s, and a low detection limit of 5 mg/dL of LDL molecules. The association, dissociation, and equilibrium rate constants for this immunoelectrode are found to be 1.66 M(-1) s(-1), 0.6 s(-1), and 2.77 M(-1), respectively. The long-term stability and excellent reproducibility of the proposed immunosensor indicates a suitable platform for detection of LDL or lipid molecules. This immunosensor provides an efficient platform for analysis of the antigen-antibody interactions of lipid molecules
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
650 |
|
7 |
|a Lipids
|2 NLM
|
650 |
|
7 |
|a Oxides
|2 NLM
|
650 |
|
7 |
|a Graphite
|2 NLM
|
650 |
|
7 |
|a 7782-42-5
|2 NLM
|
700 |
1 |
|
|a Kamil Reza, K
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Srivastava, Saurabh
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Agrawal, Ved Varun
|e verfasserin
|4 aut
|
700 |
1 |
|
|a John, Renu
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Malhotra, Bansi Dhar
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Langmuir : the ACS journal of surfaces and colloids
|d 1992
|g 30(2014), 14 vom: 15. Apr., Seite 4192-201
|w (DE-627)NLM098181009
|x 1520-5827
|7 nnns
|
773 |
1 |
8 |
|g volume:30
|g year:2014
|g number:14
|g day:15
|g month:04
|g pages:4192-201
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1021/la4049852
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_22
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_721
|
951 |
|
|
|a AR
|
952 |
|
|
|d 30
|j 2014
|e 14
|b 15
|c 04
|h 4192-201
|