Verification of the Westervelt equation for focused transducers

This study investigates the validity of the Westervelt equation for focused transducers. The angular spectrum method is employed to analyze the second-harmonic acoustic field under the weakly nonlinear approximation. Although it is well known that the Westervelt equation is accurate for the case of...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 58(2011), 5 vom: 01. Mai, Seite 1097-101
1. Verfasser: Jing, Yun (VerfasserIn)
Weitere Verfasser: Shen, Du, Clement, Greg T
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2011
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Letter
LEADER 01000naa a22002652 4500
001 NLM208706240
003 DE-627
005 20231224004449.0
007 cr uuu---uuuuu
008 231224s2011 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2011.1910  |2 doi 
028 5 2 |a pubmed24n0696.xml 
035 |a (DE-627)NLM208706240 
035 |a (NLM)21622065 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Jing, Yun  |e verfasserin  |4 aut 
245 1 0 |a Verification of the Westervelt equation for focused transducers 
264 1 |c 2011 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 08.09.2011 
500 |a Date Revised 30.05.2011 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a This study investigates the validity of the Westervelt equation for focused transducers. The angular spectrum method is employed to analyze the second-harmonic acoustic field under the weakly nonlinear approximation. Although it is well known that the Westervelt equation is accurate for the case of quasi-plane waves, the present work demonstrates accurate solution for the highly focused case of a spherically-curved ultrasound transducer having an aperture angle of 80°. It is further found that the solution error is inversely dependent on the nonlinearity coefficient 
650 4 |a Letter 
700 1 |a Shen, Du  |e verfasserin  |4 aut 
700 1 |a Clement, Greg T  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 58(2011), 5 vom: 01. Mai, Seite 1097-101  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:58  |g year:2011  |g number:5  |g day:01  |g month:05  |g pages:1097-101 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2011.1910  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 58  |j 2011  |e 5  |b 01  |c 05  |h 1097-101