Concept of a spectrometer for resonant inelastic X-ray scattering with parallel detection in incoming and outgoing photon energies

A spectrometer for resonant inelastic X-ray scattering (RIXS) is proposed where imaging and dispersion actions in two orthogonal planes are combined to deliver a full two-dimensional map of RIXS intensity in one shot with parallel detection at incoming hv(in) and outgoing hv(out) photon energies. Pr...

Description complète

Détails bibliographiques
Publié dans:Journal of synchrotron radiation. - 1994. - 17(2010), 1 vom: 19. Jan., Seite 103-6
Auteur principal: Strocov, V N (Auteur)
Format: Article en ligne
Langue:English
Publié: 2010
Accès à la collection:Journal of synchrotron radiation
Sujets:Evaluation Study Journal Article
LEADER 01000caa a22002652c 4500
001 NLM193932202
003 DE-627
005 20250211034823.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049509051097  |2 doi 
028 5 2 |a pubmed25n0646.xml 
035 |a (DE-627)NLM193932202 
035 |a (NLM)20029118 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Strocov, V N  |e verfasserin  |4 aut 
245 1 0 |a Concept of a spectrometer for resonant inelastic X-ray scattering with parallel detection in incoming and outgoing photon energies 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 10.03.2010 
500 |a Date Revised 10.12.2019 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a A spectrometer for resonant inelastic X-ray scattering (RIXS) is proposed where imaging and dispersion actions in two orthogonal planes are combined to deliver a full two-dimensional map of RIXS intensity in one shot with parallel detection at incoming hv(in) and outgoing hv(out) photon energies. Preliminary ray-tracing simulations with a typical undulator beamline demonstrate a resolving power well above 11000 with both hv(in) and hv(out) near 930 eV, with a vast potential for improvement. Combining this instrument - nicknamed hv(2) spectrometer - with an X-ray free-electron laser source simplifies its technical implementation and enables efficient time-resolved RIXS experiments 
650 4 |a Evaluation Study 
650 4 |a Journal Article 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 17(2010), 1 vom: 19. Jan., Seite 103-6  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:17  |g year:2010  |g number:1  |g day:19  |g month:01  |g pages:103-6 
856 4 0 |u http://dx.doi.org/10.1107/S0909049509051097  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 17  |j 2010  |e 1  |b 19  |c 01  |h 103-6