Solvent dependent friction force response of polystyrene brushes prepared by surface initiated polymerization

Polystyrene (PS) brushes were prepared on oxide passivated silicon by the surface initiated polymerization (SIP) technique. From an AIBN-type free radical initiator, which was silanized and immobilized on silicon wafers, styrene brushes were directly polymerized and grafted from the surface. The for...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 23(2007), 24 vom: 20. Nov., Seite 12196-201
1. Verfasser: Limpoco, F T (VerfasserIn)
Weitere Verfasser: Advincula, Rigoberto C, Perry, Scott S
Format: Aufsatz
Sprache:English
Veröffentlicht: 2007
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM174507658
003 DE-627
005 20231223140056.0
007 tu
008 231223s2007 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0582.xml 
035 |a (DE-627)NLM174507658 
035 |a (NLM)17949015 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Limpoco, F T  |e verfasserin  |4 aut 
245 1 0 |a Solvent dependent friction force response of polystyrene brushes prepared by surface initiated polymerization 
264 1 |c 2007 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 08.02.2008 
500 |a Date Revised 13.11.2007 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Polystyrene (PS) brushes were prepared on oxide passivated silicon by the surface initiated polymerization (SIP) technique. From an AIBN-type free radical initiator, which was silanized and immobilized on silicon wafers, styrene brushes were directly polymerized and grafted from the surface. The formation of the initiator monolayer and, subsequently, the polymer brush on the surface were monitored by X-ray photoelectron spectroscopy (XPS) and ellipsometry. Friction force measurements were performed by atomic force microscopy (AFM), using a 5 microm SiO2 colloidal sphere tip and under systematically varied solvent environments (nonpolar to polar), to demonstrate the dependence of brush lubricity on solvation. The relative uptake of solvents in the PS brush was determined by quartz crystal microbalance (QCM), and it correlates well with friction data. It is surmised that, in poor solvent environments, the polymer brush exists in a collapsed conformation, giving rise to the higher observed friction response 
650 4 |a Journal Article 
700 1 |a Advincula, Rigoberto C  |e verfasserin  |4 aut 
700 1 |a Perry, Scott S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 23(2007), 24 vom: 20. Nov., Seite 12196-201  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:23  |g year:2007  |g number:24  |g day:20  |g month:11  |g pages:12196-201 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 23  |j 2007  |e 24  |b 20  |c 11  |h 12196-201