Quantitative nanotribology by AFM : a novel universal calibration platform

The quantitative determination of friction forces by atomic force microscopy (AFM) in nanotribology requires the conversion of the output voltage signal of the sector area-sensitive photodiode to force using (a) the torsional spring constant of the cantilever and (b) the lateral sensitivity of the p...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 22(2006), 5 vom: 28. Feb., Seite 2340-50
1. Verfasser: Tocha, Ewa (VerfasserIn)
Weitere Verfasser: Schönherr, Holger, Vancso, G Julius
Format: Aufsatz
Sprache:English
Veröffentlicht: 2006
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
Beschreibung
Zusammenfassung:The quantitative determination of friction forces by atomic force microscopy (AFM) in nanotribology requires the conversion of the output voltage signal of the sector area-sensitive photodiode to force using (a) the torsional spring constant of the cantilever and (b) the lateral sensitivity of the photodiode. Many existing methods provide calibration factors with large errors and suffer from poor reproducibility. We report on the fabrication, validation, and application of a new, universally applicable standard specimen that enables one to accurately calibrate all types of AFM cantilevers and tips for quantitative friction force measurements. The Si(100) calibration standard, which exhibits 30 and 50 mum wide notches with tilt angles theta between 20 degrees and 35 degrees with respect to the wafer surface, was fabricated by focused ion beam (FIB) milling. The quantification of friction forces obtained on this universal standard specimen using a direct method (the improved wedge calibration method, as introduced by Ogletree, Carpick, and Salmeron Rev. Sci. Instrum. 1996, 67, 3298-3306), which yields (a) and (b) simultaneously, was critically tested for various types of Si3N4 integrated cantilever-tip assemblies. The error in the calibration factors obtained was found to be ca. 5%, which is a significant improvement compared to errors of 30-50% observed for the often applied two-step calibration procedures of cantilever lateral force constant and photodiode sensitivity. As demonstrated for oxidized Si(100), thin films of poly(methyl methacrylate) (PMMA), and micropatterned self-assembled monolayers (SAMs) on gold, the calibration of various V-shaped and single beam cantilevers based on the application of the new universal standard in conjunction with the direct wedge method proposed allows one to conveniently perform quantitative nanotribological measurements for a wide range of materials and applications
Beschreibung:Date Completed 16.05.2007
Date Revised 21.02.2006
published: Print
Citation Status PubMed-not-MEDLINE
ISSN:1520-5827