The new materials processing beamline at the SRS Daresbury, MPW6.2

A new beamline (MPW6.2) has been designed and built for the study of materials during processing where three synchrotron techniques, SAXS, WAXS and XAS, are available simultaneously. It has been demonstrated that Rietveld refinable data can be collected from silicon SRM 640b over a 60 degrees range...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 11(2004), Pt 2 vom: 01. März, Seite 163-70
1. Verfasser: Cernik, R J (VerfasserIn)
Weitere Verfasser: Barnes, P, Bushnell-Wye, G, Dent, A J, Diakun, G P, Flaherty, J V, Greaves, G N, Heeley, E L, Helsby, W, Jacques, S D M, Kay, J, Rayment, T, Ryan, A, Tang, C C, Terrill, N J
Format: Aufsatz
Sprache:English
Veröffentlicht: 2004
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Evaluation Study Journal Article Research Support, Non-U.S. Gov't Minerals Polypropylenes
LEADER 01000naa a22002652 4500
001 NLM14664817X
003 DE-627
005 20231223041635.0
007 tu
008 231223s2004 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0489.xml 
035 |a (DE-627)NLM14664817X 
035 |a (NLM)14960781 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Cernik, R J  |e verfasserin  |4 aut 
245 1 4 |a The new materials processing beamline at the SRS Daresbury, MPW6.2 
264 1 |c 2004 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 11.05.2004 
500 |a Date Revised 10.12.2019 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a A new beamline (MPW6.2) has been designed and built for the study of materials during processing where three synchrotron techniques, SAXS, WAXS and XAS, are available simultaneously. It has been demonstrated that Rietveld refinable data can be collected from silicon SRM 640b over a 60 degrees range in a time scale of 1 s. The data have been refined to a chi(2) of 2.4, the peaks fitting best to a Pearson VII function or with fundamental parameters. The peak halfwidths have been found to be approximately constant at 0.06 degrees over a 120 degrees angular range indicating that the instrumental resolution function has matched its design specification. A quantitative comparison of data sets collected on the same isotactic polypropylene system on MPW6.2 and DUBBLE at the ESRF shows a 17% improvement in angular resolution and a 1.8 improvement in peak-to-background ratio with the RAPID2 system; the ESRF data vary more smoothly across detector channels. The time-dependent wide-angle XRD was tested by comparing a hydration reaction of gypsum-bassanite-anhydrite with energy-dispersive data collected on the same system on the same time scale. Three sample data sets from the reaction were selected for analysis and gave an average chi(2) of 3.8. The Rietveld-refined lattice parameters are a good match with published values and the corresponding errors show a mean value of 3.3 x 10(-4). The data have also been analysed by the Pawley decomposition phase-modelling technique demonstrating the ability of the station to quickly and accurately identify new phases. The combined SAXS/WAXS capability of the station was tested with the crystallization and spinodal decomposition of a very dilute polymer system. Our measurements show that the crystallization of a high-density co-polymer (E76B38) as low as 0.5% by weight can be observed in solution in hexane. The WAXS and SAXS data sets were collected on the same time scale. The SAXS detector was calibrated using a collagen sample that gave 30 orders of diffraction in 1 s of data collection. The combined XRD and XAS measurement capability of the station was tested by observing the collapse and re-crystallization of zinc-exchanged zeolite A (zeolite Zn/Na-A). Previous studies of this material on station 9.3 at the SRS were compared with those from the new station. A time improvement of 38 was observed with better quality counting statistics. The improved angular resolution from the WAXS detector enabled new peaks to be identified 
650 4 |a Evaluation Study 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Minerals  |2 NLM 
650 7 |a Polypropylenes  |2 NLM 
700 1 |a Barnes, P  |e verfasserin  |4 aut 
700 1 |a Bushnell-Wye, G  |e verfasserin  |4 aut 
700 1 |a Dent, A J  |e verfasserin  |4 aut 
700 1 |a Diakun, G P  |e verfasserin  |4 aut 
700 1 |a Flaherty, J V  |e verfasserin  |4 aut 
700 1 |a Greaves, G N  |e verfasserin  |4 aut 
700 1 |a Heeley, E L  |e verfasserin  |4 aut 
700 1 |a Helsby, W  |e verfasserin  |4 aut 
700 1 |a Jacques, S D M  |e verfasserin  |4 aut 
700 1 |a Kay, J  |e verfasserin  |4 aut 
700 1 |a Rayment, T  |e verfasserin  |4 aut 
700 1 |a Ryan, A  |e verfasserin  |4 aut 
700 1 |a Tang, C C  |e verfasserin  |4 aut 
700 1 |a Terrill, N J  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 11(2004), Pt 2 vom: 01. März, Seite 163-70  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:11  |g year:2004  |g number:Pt 2  |g day:01  |g month:03  |g pages:163-70 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 11  |j 2004  |e Pt 2  |b 01  |c 03  |h 163-70