Synchrotron-radiation X-ray topography of surface strain in large-diameter silicon wafers

Using a 300 mm-wide monochromatic X-ray beam obtained at beamline BL20B2 of SPring-8, the difference in surface-strain distribution caused by various steps of silicon-wafer manufacturing, i.e. slicing, lapping, etching, grinding and polishing, was studied. The asymmetric 511 reflection of 21.45 keV...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1999. - 9(2002), Pt 3 vom: 01. Mai, Seite 166-8
1. Verfasser: Kawado, S (VerfasserIn)
Weitere Verfasser: Iida, S, Yamaguchi, S, Kimura, S, Hirose, Y, Kajiwara, K, Chikaura, Y, Umeno, M
Format: Aufsatz
Sprache:English
Veröffentlicht: 2002
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM118513834
003 DE-627
005 20250203055444.0
007 tu
008 231222s2002 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0395.xml 
035 |a (DE-627)NLM118513834 
035 |a (NLM)11972372 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kawado, S  |e verfasserin  |4 aut 
245 1 0 |a Synchrotron-radiation X-ray topography of surface strain in large-diameter silicon wafers 
264 1 |c 2002 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 14.08.2002 
500 |a Date Revised 05.06.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Using a 300 mm-wide monochromatic X-ray beam obtained at beamline BL20B2 of SPring-8, the difference in surface-strain distribution caused by various steps of silicon-wafer manufacturing, i.e. slicing, lapping, etching, grinding and polishing, was studied. The asymmetric 511 reflection of 21.45 keV X-rays, incident at a glancing angle of 0.26 degrees, was used to obtain topographs over the whole surface of a 200 mm-diameter (100) CZ silicon wafer. Differences in crystallinity and in warp between the surfaces at different steps of the manufacturing process (firstly after the lapping following the slicing, and then after successive etching, grinding and polishing) were clearly observed. The former gave a topographic image over the whole area with a one-shot exposure because of their wide rocking curves (50-70 arcsec FWHM), which indicate poor crystallinity. The latter, on the other hand, showed sharper curves (4-5 arcsec FWHM), which indicate good crystallinity in local areas, and the existence of warp, and therefore required step scanning of omega-rotation to cover the whole surface in topography measurements. The effect of each step in the process is also discussed 
650 4 |a Journal Article 
700 1 |a Iida, S  |e verfasserin  |4 aut 
700 1 |a Yamaguchi, S  |e verfasserin  |4 aut 
700 1 |a Kimura, S  |e verfasserin  |4 aut 
700 1 |a Hirose, Y  |e verfasserin  |4 aut 
700 1 |a Kajiwara, K  |e verfasserin  |4 aut 
700 1 |a Chikaura, Y  |e verfasserin  |4 aut 
700 1 |a Umeno, M  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1999  |g 9(2002), Pt 3 vom: 01. Mai, Seite 166-8  |w (DE-627)NLM09824129X  |x 0909-0495  |7 nnns 