Fast multigrid fluorescent ion chamber with 0.1 ms time response

A fast multigrid ion chamber for the detection of fluorescent X-rays has been developed. The structure of 17 grids with close separation was employed to maximize the time response as well as to give sufficient detection efficiency. The measured rise/fall response time to cyclic X-rays was shorter th...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1999. - 9(2002), Pt 2 vom: 01. März, Seite 99-102
1. Verfasser: Suzuki, Motohiro (VerfasserIn)
Weitere Verfasser: Kawamura, Naomi, Lytle, Farrel W, Ishikawa, Tetsuya
Format: Aufsatz
Sprache:English
Veröffentlicht: 2002
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM117578614
003 DE-627
005 20250203035024.0
007 tu
008 231222s2002 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0392.xml 
035 |a (DE-627)NLM117578614 
035 |a (NLM)11872931 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Suzuki, Motohiro  |e verfasserin  |4 aut 
245 1 0 |a Fast multigrid fluorescent ion chamber with 0.1 ms time response 
264 1 |c 2002 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 31.05.2002 
500 |a Date Revised 05.06.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A fast multigrid ion chamber for the detection of fluorescent X-rays has been developed. The structure of 17 grids with close separation was employed to maximize the time response as well as to give sufficient detection efficiency. The measured rise/fall response time to cyclic X-rays was shorter than that of an existing three-grid ion chamber by more than one order of magnitude. A 0.13 ms time response was obtained at the 500 V applied voltage, where the detector can stably operate without any discharge. The available frequency range is as high as 1 kHz with a practical amplitude response 
650 4 |a Journal Article 
700 1 |a Kawamura, Naomi  |e verfasserin  |4 aut 
700 1 |a Lytle, Farrel W  |e verfasserin  |4 aut 
700 1 |a Ishikawa, Tetsuya  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1999  |g 9(2002), Pt 2 vom: 01. März, Seite 99-102  |w (DE-627)NLM09824129X  |x 0909-0495  |7 nnns 
773 1 8 |g volume:9  |g year:2002  |g number:Pt 2  |g day:01  |g month:03  |g pages:99-102 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 9  |j 2002  |e Pt 2  |b 01  |c 03  |h 99-102