The XMaS beamline at ESRF : instrumental developments and high-resolution diffraction studies

The beamline, which is situated on a bending magnet at ESRF, comprises a unique combination of instrumentation for high-resolution and magnetic single-crystal diffraction. White-beam operation is possible, as well as focused and unfocused monochromatic modes. In addition to an eleven-axis Huber diff...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1999. - 8(2001), Pt 6 vom: 01. Nov., Seite 1172-81
1. Verfasser: Brown, S D (VerfasserIn)
Weitere Verfasser: Bouchenoire, L, Bowyer, D, Kervin, J, Laundy, D, Longfield, M J, Mannix, D, Paul, D F, Stunault, A, Thompson, P, Cooper, M J, Lucas, C A, Stirling, W G
Format: Aufsatz
Sprache:English
Veröffentlicht: 2001
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM115742042
003 DE-627
005 20250202221616.0
007 tu
008 231222s2001 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0386.xml 
035 |a (DE-627)NLM115742042 
035 |a (NLM)11679768 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Brown, S D  |e verfasserin  |4 aut 
245 1 4 |a The XMaS beamline at ESRF  |b instrumental developments and high-resolution diffraction studies 
264 1 |c 2001 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 14.01.2002 
500 |a Date Revised 05.06.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The beamline, which is situated on a bending magnet at ESRF, comprises a unique combination of instrumentation for high-resolution and magnetic single-crystal diffraction. White-beam operation is possible, as well as focused and unfocused monochromatic modes. In addition to an eleven-axis Huber diffractometer, which facilitates simple operation in both vertical and horizontal scattering geometries, there is an in-vacuum polarization analyser and slit system, mirrors for harmonic rejection, sub 4.2 K and 1 Tesla magnetic field sample environment, plus a diamond phase plate for polarization conditioning. The instrumentation developed specifically for this beamline is described, and its use illustrated by recent scientific results 
650 4 |a Journal Article 
700 1 |a Bouchenoire, L  |e verfasserin  |4 aut 
700 1 |a Bowyer, D  |e verfasserin  |4 aut 
700 1 |a Kervin, J  |e verfasserin  |4 aut 
700 1 |a Laundy, D  |e verfasserin  |4 aut 
700 1 |a Longfield, M J  |e verfasserin  |4 aut 
700 1 |a Mannix, D  |e verfasserin  |4 aut 
700 1 |a Paul, D F  |e verfasserin  |4 aut 
700 1 |a Stunault, A  |e verfasserin  |4 aut 
700 1 |a Thompson, P  |e verfasserin  |4 aut 
700 1 |a Cooper, M J  |e verfasserin  |4 aut 
700 1 |a Lucas, C A  |e verfasserin  |4 aut 
700 1 |a Stirling, W G  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1999  |g 8(2001), Pt 6 vom: 01. Nov., Seite 1172-81  |w (DE-627)NLM09824129X  |x 0909-0495  |7 nnns 
773 1 8 |g volume:8  |g year:2001  |g number:Pt 6  |g day:01  |g month:11  |g pages:1172-81 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 8  |j 2001  |e Pt 6  |b 01  |c 11  |h 1172-81