Short-term results of a hybrid ingrowth glenoid in anatomic total shoulder arthroplasty : a radiographic analysis for radiolucent lines and osteointegration using tomosynthesis

© 2025 The Author(s).

Détails bibliographiques
Publié dans:JSES international. - 2020. - 9(2025), 5 vom: 07. Sept., Seite 1645-1652
Auteur principal: Takayama, Kazumasa (Auteur)
Autres auteurs: Ichimura, Atsuhiko, Ito, Hiromu
Format: Article en ligne
Langue:English
Publié: 2025
Accès à la collection:JSES international
Sujets:Journal Article Glenoid Hybrid glenoid Loosening Radiolucent line Tomosynthesis Total shoulder arthroplasty
Description
Résumé:© 2025 The Author(s).
Background: Loosening of the glenoid component is the most common cause of implant failure in total shoulder arthroplasty. Recently, a hybrid glenoid component with polyethylene peripheral pegs and an ingrowth central peg was developed. This study aimed to evaluate radiolucent lines (RLLs) around the pegs and osteointegration around the central metal peg in the hybrid glenoid component using tomosynthesis
Methods: Nineteen patients with a hybrid glenoid and 18 with a cemented all-polyethylene glenoid were included. Radiographic lucency around the glenoid components was graded (Grade 0-5). To investigate the accuracy of RLL detection on plain radiographs, tomosynthesis images and plain radiographs were compared 2 years postoperatively. The zone of spot welds (a sign of osteointegration) and RLL in the hybrid glenoids were evaluated
Results: The incidence of RLL was 15.8% (Grade 1, 3/19 cases) in the hybrid glenoid component and 33.3% (Grades 1 and 3: three cases each, 6/18 cases) in the cemented all-polyethylene glenoid component; however, the difference was not statistically significant. All 19 patients achieved osteointegration around the central metal peg 8 months postoperatively, and no progression of the RLL was observed. The concordance in the detection of RLL between tomosynthesis and plain radiography was 89.4% (17/19 cases) in the hybrid glenoid group and 72.2% (13/18 cases) in the cemented all-polyethylene group. However, plain radiography tended to underestimate RLL in both groups
Conclusion: The hybrid glenoid component may be a viable alternative to the cemented all-polyethylene glenoid. Tomosynthesis may be a new and effective modality for evaluating glenoid loosening
Description:Date Completed 06.10.2025
Date Revised 08.10.2025
published: Electronic-eCollection
Citation Status PubMed-not-MEDLINE
ISSN:2666-6383