The 10 m collimated Rowland spectrometer at the MAX IV Veritas beamline

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 32(2025), Pt 5 vom: 01. Sept., Seite 1328-1345
1. Verfasser: Agåker, Marcus (VerfasserIn)
Weitere Verfasser: Englund, Carl Johan, Ekholm, Victor, Kjellsson, Ludvig, Sjöblom, Peter, Pickworth, Louisa, Söderström, Johan, Johansson, Niklas, Ghosh, Anirudha, Tokushima, Takashi, Caputo, Marco, Forsberg, Johan, Felcsuti, Gábor, Fredriksson, Pierre, Malki, Suleyman, Wassdahl, Nial, Såthe, Conny, Rubensson, Jan Erik
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2025
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article RIXS instrument soft X-rays spectrometer synchrotron
LEADER 01000caa a22002652c 4500
001 NLM389947644
003 DE-627
005 20250910232046.0
007 cr uuu---uuuuu
008 250723s2025 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577525005478  |2 doi 
028 5 2 |a pubmed25n1563.xml 
035 |a (DE-627)NLM389947644 
035 |a (NLM)40698855 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Agåker, Marcus  |e verfasserin  |4 aut 
245 1 4 |a The 10 m collimated Rowland spectrometer at the MAX IV Veritas beamline 
264 1 |c 2025 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 10.09.2025 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a A grazing-incidence Rowland spectrometer with a collimating element for resonant inelastic soft X-ray scattering at the Veritas beamline at MAX IV, Lund, Sweden, is presented. The instrument is designed to operate in the 250-950 eV range, providing >30000 resolving power in first order. The inherent temporal resolution of the delay-line detector enables time-resolved experiments on the 270 ps time-scale and also allows for so-called time-gating which significantly improves the signal-to-noise ratio. The instrument is able to rotate around the sample position in the horizontal plane, which enables measurements of the momentum transfer in the X-ray scattering event. The instrument is prepared for installation of a polarimeter to provide full characterization of energy, momentum and polarization of the scattered photons. The design is evaluated using spectral measurements, ray-tracing, vibration and motion measurements 
650 4 |a Journal Article 
650 4 |a RIXS 
650 4 |a instrument 
650 4 |a soft X-rays 
650 4 |a spectrometer 
650 4 |a synchrotron 
700 1 |a Englund, Carl Johan  |e verfasserin  |4 aut 
700 1 |a Ekholm, Victor  |e verfasserin  |4 aut 
700 1 |a Kjellsson, Ludvig  |e verfasserin  |4 aut 
700 1 |a Sjöblom, Peter  |e verfasserin  |4 aut 
700 1 |a Pickworth, Louisa  |e verfasserin  |4 aut 
700 1 |a Söderström, Johan  |e verfasserin  |4 aut 
700 1 |a Johansson, Niklas  |e verfasserin  |4 aut 
700 1 |a Ghosh, Anirudha  |e verfasserin  |4 aut 
700 1 |a Tokushima, Takashi  |e verfasserin  |4 aut 
700 1 |a Caputo, Marco  |e verfasserin  |4 aut 
700 1 |a Forsberg, Johan  |e verfasserin  |4 aut 
700 1 |a Felcsuti, Gábor  |e verfasserin  |4 aut 
700 1 |a Fredriksson, Pierre  |e verfasserin  |4 aut 
700 1 |a Malki, Suleyman  |e verfasserin  |4 aut 
700 1 |a Wassdahl, Nial  |e verfasserin  |4 aut 
700 1 |a Såthe, Conny  |e verfasserin  |4 aut 
700 1 |a Rubensson, Jan Erik  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 32(2025), Pt 5 vom: 01. Sept., Seite 1328-1345  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:32  |g year:2025  |g number:Pt 5  |g day:01  |g month:09  |g pages:1328-1345 
856 4 0 |u http://dx.doi.org/10.1107/S1600577525005478  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 32  |j 2025  |e Pt 5  |b 01  |c 09  |h 1328-1345