Novel fixed-target serial crystallography flip-holder for macromolecular crystallography beamlines at synchrotron radiation sources

open access.

Détails bibliographiques
Publié dans:Journal of synchrotron radiation. - 1994. - 32(2025), Pt 2 vom: 01. März, Seite 315-320
Auteur principal: Gu, Do Heon (Auteur)
Autres auteurs: Jeong, Dong Tak, Eo, Cheolsoo, Seo, Pil Won, Kim, Jeong Sun, Park, Suk Youl
Format: Article en ligne
Langue:English
Publié: 2025
Accès à la collection:Journal of synchrotron radiation
Sujets:Journal Article fixed-target holder flip-holder room temperature serial crystallography synchrotron
LEADER 01000caa a22002652c 4500
001 NLM383813697
003 DE-627
005 20250509063053.0
007 cr uuu---uuuuu
008 250507s2025 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577524011664  |2 doi 
028 5 2 |a pubmed25n1341.xml 
035 |a (DE-627)NLM383813697 
035 |a (NLM)39899406 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Gu, Do Heon  |e verfasserin  |4 aut 
245 1 0 |a Novel fixed-target serial crystallography flip-holder for macromolecular crystallography beamlines at synchrotron radiation sources 
264 1 |c 2025 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 12.03.2025 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a Synchrotron serial crystallography (SSX) is an emerging method for determining crystal structure at room temperature using synchrotron radiation facilities. Despite the various approaches available, reducing sample consumption, removing mother liquid from crystal solution, soaking small molecules for protein-ligand complex structure and prevention of sample dehydration are still challenging problems to be overcome in SSX. Therefore, we have developed a new flip-type fixed-target SSX sample holder for conventional protein crystallography beamlines based on nylon mesh and kapton film. The potential of the flip-holder was evaluated in an SSX experiment with lysozyme crystals at room temperature. About 19600 diffraction images were collected during 40 minutes using a repetition rate of 10 Hz at the 11C beamline of the Pohang Accelerator Laboratory, and the crystal structure of lysozyme was determined at 1.89 Å resolution. This straightforward flip-holder can be used in synchrotron beamlines for routine crystallography 
650 4 |a Journal Article 
650 4 |a fixed-target holder 
650 4 |a flip-holder 
650 4 |a room temperature 
650 4 |a serial crystallography 
650 4 |a synchrotron 
700 1 |a Jeong, Dong Tak  |e verfasserin  |4 aut 
700 1 |a Eo, Cheolsoo  |e verfasserin  |4 aut 
700 1 |a Seo, Pil Won  |e verfasserin  |4 aut 
700 1 |a Kim, Jeong Sun  |e verfasserin  |4 aut 
700 1 |a Park, Suk Youl  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 32(2025), Pt 2 vom: 01. März, Seite 315-320  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:32  |g year:2025  |g number:Pt 2  |g day:01  |g month:03  |g pages:315-320 
856 4 0 |u http://dx.doi.org/10.1107/S1600577524011664  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 32  |j 2025  |e Pt 2  |b 01  |c 03  |h 315-320