245 1 0 |a Development of MHz X-ray phase contrast imaging at the European XFEL 
264 1 |c 2025 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.11.2024 
500 |a published: Print-Electronic 
500 |a Citation Status Publisher 
520 |a open access. 
520 |a We report on recent developments that enable megahertz hard X-ray phase contrast imaging (MHz XPCI) experiments at the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument of the European XFEL facility (EuXFEL). We describe the technical implementation of the key components, including an MHz fast camera and a modular indirect X-ray microscope system based on fast scintillators coupled through a high-resolution optical microscope, which enable full-field X-ray microscopy with phase contrast of fast and irreversible phenomena. The image quality for MHz XPCI data showed significant improvement compared with a pilot demonstration of the technique using parallel beam illumination, which also allows access to up to 24 keV photon energies at the SPB/SFX instrument of the EuXFEL. With these developments, MHz XPCI was implemented as a new method offered for a broad user community (academic and industrial) and is accessible via standard user proposals. Furthermore, intra-train pulse diagnostics with a high few-micrometre spatial resolution and recording up to 128 images of consecutive pulses in a train at up to 1.1 MHz repetition rate is available upstream of the instrument. Together with the diagnostic camera upstream of the instrument and the MHz XPCI setup at the SPB/SFX instrument, simultaneous two-plane measurements for future beam studies and feedback for machine parameter tuning are now possible 
650 4 |a Journal Article 
650 4 |a European XFEL 
650 4 |a X-ray phase contrast imaging 
650 4 |a indirect MHz X-ray detector 
650 4 |a megahertz sampling 
650 4 |a pulse-resolved imaging 
700 1 |a Moško, Daniel  |e verfasserin  |4 aut 
700 1 |a Asimakopoulou, Eleni Myrto  |e verfasserin  |4 aut 
700 1 |a Bellucci, Valerio  |e verfasserin  |4 aut 
700 1 |a Birnšteinová, Šarlota  |e verfasserin  |4 aut 
700 1 |a Bean, Richard  |e verfasserin  |4 aut 
700 1 |a Letrun, Romain  |e verfasserin  |4 aut 
700 1 |a Kim, Chan  |e verfasserin  |4 aut 
700 1 |a Kirkwood, Henry  |e verfasserin  |4 aut 
700 1 |a Giovanetti, Gabriele  |e verfasserin  |4 aut 
700 1 |a Jardon, Nerea  |e verfasserin  |4 aut 
700 1 |a Szuba, Janusz  |e verfasserin  |4 aut 
700 1 |a Guest, Trey  |e verfasserin  |4 aut 
700 1 |a Koch, Andreas  |e verfasserin  |4 aut 
700 1 |a Grünert, Jan  |e verfasserin  |4 aut 
700 1 |a Szeles, Peter  |e verfasserin  |4 aut 
700 1 |a Villanueva-Perez, Pablo  |e verfasserin  |4 aut 
700 1 |a Reuter, Fabian  |e verfasserin  |4 aut 
700 1 |a Ohl, Claus Dieter  |e verfasserin  |4 aut 
700 1 |a Noack, Mike Andreas  |e verfasserin  |4 aut 
700 1 |a Garcia-Moreno, Francisco  |e verfasserin  |4 aut 
700 1 |a Kuglerová-Valdová, Zuzana  |e verfasserin  |4 aut 
700 1 |a Juha, Libor  |e verfasserin  |4 aut 
700 1 |a Nikl, Martin  |e verfasserin  |4 aut 
700 1 |a Yashiro, Wataru  |e verfasserin  |4 aut 
700 1 |a Soyama, Hitoshi  |e verfasserin  |4 aut 
700 1 |a Eakins, Daniel  |e verfasserin  |4 aut 
700 1 |a Korsunsky, Alexander M  |e verfasserin  |4 aut 
700 1 |a Uličný, Jozef  |e verfasserin  |4 aut 
700 1 |a Meents, Alke  |e verfasserin  |4 aut 
700 1 |a Chapman, Henry N  |e verfasserin  |4 aut 
700 1 |a Mancuso, Adrian P  |e verfasserin  |4 aut 
700 1 |a Sato, Tokushi  |e verfasserin  |4 aut 
700 1 |a Vagovič, Patrik  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g (2024) vom: 01. Jan.  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g year:2024  |g day:01  |g month:01 
856 4 0 |u http://dx.doi.org/10.1107/S160057752400986X  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |j 2024  |b 01  |c 01