Compact, high-flow, water-based, turbulent-mixing, condensation aerosol concentrator for collection of spot samples

A new high-flow, compact aerosol concentrator, using rapid, turbulent mixing to grow aerosol particles into droplets for dry spot sample collection, has been designed and tested. The "TCAC (Turbulent-mixing, Condensation Aerosol Concentrator)" is composed of a saturator for generating hot...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Aerosol science and technology : the journal of the American Association for Aerosol Research. - 1989. - 58(2024), 8 vom: 07., Seite 889-901
1. Verfasser: Zervaki, Orthodoxia (VerfasserIn)
Weitere Verfasser: Dionysiou, Dionysios D, Kulkarni, Pramod
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Aerosol science and technology : the journal of the American Association for Aerosol Research
Schlagworte:Journal Article
Beschreibung
Zusammenfassung:A new high-flow, compact aerosol concentrator, using rapid, turbulent mixing to grow aerosol particles into droplets for dry spot sample collection, has been designed and tested. The "TCAC (Turbulent-mixing, Condensation Aerosol Concentrator)" is composed of a saturator for generating hot vapor, a mixing section where the hot vapor mixes with the cold aerosol flow, a growth tube where condensational droplet growth primarily occurs, and a converging nozzle that focuses the droplets into a beam. The prototype concentrator utilizes an aerosol sample flow rate of 4 L min-1. The TCAC was optimized by varying the operating conditions, such as relative humidity of the aerosol flow, mixing flow ratio, vapor temperature, and impaction characteristics. The results showed that particles with a diameter ≥ 25 nm can be grown to a droplet diameter > 1400 nm with near 100% efficiency. Complete activation and growth were observed at relative humidity ≥ 25% of the aerosol sample flow. A consistent spot sample with a diameter of D 90 = 1.4 mm (the diameter of a circle containing 90% of the deposited particles) was obtained regardless of the aerosol particle diameter ( d p = 20 - 1900 nm ). For fiber counting applications using phase contrast microscopy, the TCAC can reduce the sampling time, or counting uncertainty, by two to three orders of magnitude, compared to the 25-mm-filter collection. The study shows that the proposed mixing-flow scheme enables a compact spot sample collector suitable for handheld or portable applications, while still allowing for high flow rates
Beschreibung:Date Revised 12.10.2024
published: Print
Citation Status PubMed-not-MEDLINE
ISSN:0278-6826
DOI:10.1080/02786826.2024.2361050