Hybrid Passive Cooling for Power Equipment Enabled by Metal-Organic Framework

© 2024 Wiley‐VCH GmbH.

Bibliographische Detailangaben
Veröffentlicht in:Advanced materials (Deerfield Beach, Fla.). - 1998. - (2024) vom: 06. Sept., Seite e2409473
1. Verfasser: Liu, Xiangyu (VerfasserIn)
Weitere Verfasser: Li, Pengli, Liu, Yijie, Zhang, Chuan, He, Meng, Pei, Zhantao, Chen, Jie, Shi, Kunming, Liu, Fei, Wang, Wanlin, Zhang, Wang, Jiang, Pingkai, Huang, Xingyi
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Advanced materials (Deerfield Beach, Fla.)
Schlagworte:Journal Article metal‐organic frameworks radiative cooling sorption‐based evaporative cooling thermal management
LEADER 01000naa a22002652 4500
001 NLM37727139X
003 DE-627
005 20240906234013.0
007 cr uuu---uuuuu
008 240906s2024 xx |||||o 00| ||eng c
024 7 |a 10.1002/adma.202409473  |2 doi 
028 5 2 |a pubmed24n1525.xml 
035 |a (DE-627)NLM37727139X 
035 |a (NLM)39240041 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Liu, Xiangyu  |e verfasserin  |4 aut 
245 1 0 |a Hybrid Passive Cooling for Power Equipment Enabled by Metal-Organic Framework 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 06.09.2024 
500 |a published: Print-Electronic 
500 |a Citation Status Publisher 
520 |a © 2024 Wiley‐VCH GmbH. 
520 |a While providing electrical energy for human society, power equipment also consumes electricity and generate heat. Cooling equipment consumes a significant amount of electricity, further increasing energy consumption and load on the power grid. Therefore, there is an urgent need to develop low-energy and sustainable cooling technologies for power equipment. In this study, a hybrid passive cooling composite designed to enhance heat dissipation for heavy-load power equipment is introduced. Specifically, the composite material achieves outstanding radiative cooling performance with an average solar reflectance of up to 0.98, while its excellent atmospheric water harvesting performance ensures high evaporation cooling power without the need for manual water replenishment. As a result, the composite effectively lowers the temperature of outdoor heavy-load power equipment (e.g., transformers) by 25.3 °C. The excellent heat dissipation properties of the composite make it a powerful tool in safeguarding electrical systems 
650 4 |a Journal Article 
650 4 |a metal‐organic frameworks 
650 4 |a radiative cooling 
650 4 |a sorption‐based evaporative cooling 
650 4 |a thermal management 
700 1 |a Li, Pengli  |e verfasserin  |4 aut 
700 1 |a Liu, Yijie  |e verfasserin  |4 aut 
700 1 |a Zhang, Chuan  |e verfasserin  |4 aut 
700 1 |a He, Meng  |e verfasserin  |4 aut 
700 1 |a Pei, Zhantao  |e verfasserin  |4 aut 
700 1 |a Chen, Jie  |e verfasserin  |4 aut 
700 1 |a Shi, Kunming  |e verfasserin  |4 aut 
700 1 |a Liu, Fei  |e verfasserin  |4 aut 
700 1 |a Wang, Wanlin  |e verfasserin  |4 aut 
700 1 |a Zhang, Wang  |e verfasserin  |4 aut 
700 1 |a Jiang, Pingkai  |e verfasserin  |4 aut 
700 1 |a Huang, Xingyi  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Advanced materials (Deerfield Beach, Fla.)  |d 1998  |g (2024) vom: 06. Sept., Seite e2409473  |w (DE-627)NLM098206397  |x 1521-4095  |7 nnns 
773 1 8 |g year:2024  |g day:06  |g month:09  |g pages:e2409473 
856 4 0 |u http://dx.doi.org/10.1002/adma.202409473  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |j 2024  |b 06  |c 09  |h e2409473