The soft X-ray spectromicroscopy beamline BL08U1A upgrade at SSRF

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 31(2024), Pt 5 vom: 01. Sept., Seite 1393-1400
1. Verfasser: Zhen, Xiangjun (VerfasserIn)
Weitere Verfasser: Guo, Zhi, Zhang, Zengyan, Wang, Yong, Tai, Renzhong
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article elliptical polarization undulator energy resolution photon flux variable-line-space plane grating
LEADER 01000caa a22002652 4500
001 NLM376593091
003 DE-627
005 20240905233128.0
007 cr uuu---uuuuu
008 240822s2024 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577524006684  |2 doi 
028 5 2 |a pubmed24n1524.xml 
035 |a (DE-627)NLM376593091 
035 |a (NLM)39172091 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Zhen, Xiangjun  |e verfasserin  |4 aut 
245 1 4 |a The soft X-ray spectromicroscopy beamline BL08U1A upgrade at SSRF 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 05.09.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a Beamline BL08U1A is a soft X-ray spectromicroscopy beamline at Shanghai Synchrotron Radiation Facility (SSRF) that exhibits the capabilities of high spatial resolution (30 nm) and high energy resolving power (over 104). As a first-generation beamline of SSRF, owing to its continuous operation over the last ten years, an urgent upgrade of the equipment including the monochromator was deemed necessary. The upgrade work included the overall construction of the monochromator and replacement of the mirrors upstream and downstream of the monochromator. Based on its original skeleton, two elliptically cylinder mirrors were designed to focus the beam horizontally, which can increase the flux density by about three times on the exit slits. Meanwhile, the application of variable-line-space gratings in the monochromator demonstrates the dual functions of dispersing and focusing on the exit slits which can decrease abberations dramatically. After the upgrade of the main components of the beamline, the energy range is 180-2000 eV, the energy resolving power reaches 16333 244 eV and 12730 @ 401 eV, and the photon flux measured in the experimental station is over 2.45 × 109 photons s-1 (E/ΔE = 6440 @ 244 eV) 
650 4 |a Journal Article 
650 4 |a elliptical polarization undulator 
650 4 |a energy resolution 
650 4 |a photon flux 
650 4 |a variable-line-space plane grating 
700 1 |a Guo, Zhi  |e verfasserin  |4 aut 
700 1 |a Zhang, Zengyan  |e verfasserin  |4 aut 
700 1 |a Wang, Yong  |e verfasserin  |4 aut 
700 1 |a Tai, Renzhong  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 31(2024), Pt 5 vom: 01. Sept., Seite 1393-1400  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:31  |g year:2024  |g number:Pt 5  |g day:01  |g month:09  |g pages:1393-1400 
856 4 0 |u http://dx.doi.org/10.1107/S1600577524006684  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 31  |j 2024  |e Pt 5  |b 01  |c 09  |h 1393-1400