|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM376431288 |
003 |
DE-627 |
005 |
20240819232521.0 |
007 |
cr uuu---uuuuu |
008 |
240819s2024 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1002/adma.202404656
|2 doi
|
028 |
5 |
2 |
|a pubmed24n1506.xml
|
035 |
|
|
|a (DE-627)NLM376431288
|
035 |
|
|
|a (NLM)39155814
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Chen, Yancheng
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Flexible Single Microwire X-Ray Detector with Ultrahigh Sensitivity for Portable Radiation Detection System
|
264 |
|
1 |
|c 2024
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Revised 19.08.2024
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status Publisher
|
520 |
|
|
|a © 2024 Wiley‐VCH GmbH.
|
520 |
|
|
|a Sensitive, flexible, and low false alarm rate X-ray detector is crucial for medical diagnosis, industrial inspection, and scientific research. However, most semiconductors for X-ray detectors are susceptible to interference from ambient light, and their high thickness hinders their application in wearable electronics. Herein, a flexible visible-blind and ultraviolet-blind X-ray detector based on Indium-doped Gallium oxide (Ga2O3:In) single microwire is prepared. Joint experiment-theory characterizations reveal that the Ga2O3:In microwire possess a high crystal quality, large band gap, and satisfactory stability, and reliability. On this basis, an extraordinary sensitivity of 5.9 × 105 µC Gyair -1 cm-2 and a low detection limit of 67.4 nGyair s-1 are achieved based on the prepared Ag/Ga2O3:In/Ag device, which has outstanding operation stability and excellent high temperature stability. Taking advantage of the flexible properties of the single microwire, a portable X-ray detection system is demonstrated that shows the potential to adapt to flexible and lightweight formats. The proposed X-ray detection system enables real-time monitor for X-rays, which can be displayed on the user interface. More importantly, it has excellent resistance to natural light interference, showing a low false alarm rate. This work provides a feasible method for exploring high-performance flexible integrated micro/nano X-ray detection devices
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Ga2O3
|
650 |
|
4 |
|a X‐ray detector
|
650 |
|
4 |
|a flexible
|
650 |
|
4 |
|a highly sensitive
|
650 |
|
4 |
|a portable radiation detection system
|
700 |
1 |
|
|a Niu, Shifeng
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Li, Ying
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Dou, Wenjie
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Yang, Xun
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Shan, Chongxin
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Shen, Guozhen
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Advanced materials (Deerfield Beach, Fla.)
|d 1998
|g (2024) vom: 19. Aug., Seite e2404656
|w (DE-627)NLM098206397
|x 1521-4095
|7 nnns
|
773 |
1 |
8 |
|g year:2024
|g day:19
|g month:08
|g pages:e2404656
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1002/adma.202404656
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|j 2024
|b 19
|c 08
|h e2404656
|