Flexible Single Microwire X-Ray Detector with Ultrahigh Sensitivity for Portable Radiation Detection System

© 2024 Wiley‐VCH GmbH.

Bibliographische Detailangaben
Veröffentlicht in:Advanced materials (Deerfield Beach, Fla.). - 1998. - (2024) vom: 19. Aug., Seite e2404656
1. Verfasser: Chen, Yancheng (VerfasserIn)
Weitere Verfasser: Niu, Shifeng, Li, Ying, Dou, Wenjie, Yang, Xun, Shan, Chongxin, Shen, Guozhen
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Advanced materials (Deerfield Beach, Fla.)
Schlagworte:Journal Article Ga2O3 X‐ray detector flexible highly sensitive portable radiation detection system
LEADER 01000naa a22002652 4500
001 NLM376431288
003 DE-627
005 20240819232521.0
007 cr uuu---uuuuu
008 240819s2024 xx |||||o 00| ||eng c
024 7 |a 10.1002/adma.202404656  |2 doi 
028 5 2 |a pubmed24n1506.xml 
035 |a (DE-627)NLM376431288 
035 |a (NLM)39155814 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Chen, Yancheng  |e verfasserin  |4 aut 
245 1 0 |a Flexible Single Microwire X-Ray Detector with Ultrahigh Sensitivity for Portable Radiation Detection System 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 19.08.2024 
500 |a published: Print-Electronic 
500 |a Citation Status Publisher 
520 |a © 2024 Wiley‐VCH GmbH. 
520 |a Sensitive, flexible, and low false alarm rate X-ray detector is crucial for medical diagnosis, industrial inspection, and scientific research. However, most semiconductors for X-ray detectors are susceptible to interference from ambient light, and their high thickness hinders their application in wearable electronics. Herein, a flexible visible-blind and ultraviolet-blind X-ray detector based on Indium-doped Gallium oxide (Ga2O3:In) single microwire is prepared. Joint experiment-theory characterizations reveal that the Ga2O3:In microwire possess a high crystal quality, large band gap, and satisfactory stability, and reliability. On this basis, an extraordinary sensitivity of 5.9 × 105 µC Gyair -1 cm-2 and a low detection limit of 67.4 nGyair s-1 are achieved based on the prepared Ag/Ga2O3:In/Ag device, which has outstanding operation stability and excellent high temperature stability. Taking advantage of the flexible properties of the single microwire, a portable X-ray detection system is demonstrated that shows the potential to adapt to flexible and lightweight formats. The proposed X-ray detection system enables real-time monitor for X-rays, which can be displayed on the user interface. More importantly, it has excellent resistance to natural light interference, showing a low false alarm rate. This work provides a feasible method for exploring high-performance flexible integrated micro/nano X-ray detection devices 
650 4 |a Journal Article 
650 4 |a Ga2O3 
650 4 |a X‐ray detector 
650 4 |a flexible 
650 4 |a highly sensitive 
650 4 |a portable radiation detection system 
700 1 |a Niu, Shifeng  |e verfasserin  |4 aut 
700 1 |a Li, Ying  |e verfasserin  |4 aut 
700 1 |a Dou, Wenjie  |e verfasserin  |4 aut 
700 1 |a Yang, Xun  |e verfasserin  |4 aut 
700 1 |a Shan, Chongxin  |e verfasserin  |4 aut 
700 1 |a Shen, Guozhen  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Advanced materials (Deerfield Beach, Fla.)  |d 1998  |g (2024) vom: 19. Aug., Seite e2404656  |w (DE-627)NLM098206397  |x 1521-4095  |7 nnns 
773 1 8 |g year:2024  |g day:19  |g month:08  |g pages:e2404656 
856 4 0 |u http://dx.doi.org/10.1002/adma.202404656  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |j 2024  |b 19  |c 08  |h e2404656