DFT Study on the Janus ZrSSe Monolayer for Its Potential Application in NO Gas Sensing

The growth of industry has resulted in increased global air pollution, necessitating the urgent development of highly sensitive gas detectors. In this work, the adsorption of the Janus ZrSSe monolayer for CO, CO2, NH3, NO, NO2, and O2 was studied by first-principles calculations. First, the stabilit...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 40(2024), 33 vom: 20. Aug., Seite 17348-17357
1. Verfasser: Zhang, Mengyang (VerfasserIn)
Weitere Verfasser: Xia, Jianjun, Guo, Gang, Guo, Gencai, Xiao, Landong, You, Manqi, Luo, Siwei, Chen, Qiong, Luo, Chaobo, He, Chaoyu, Tang, Chao
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM376168684
003 DE-627
005 20240820232605.0
007 cr uuu---uuuuu
008 240812s2024 xx |||||o 00| ||eng c
024 7 |a 10.1021/acs.langmuir.4c01480  |2 doi 
028 5 2 |a pubmed24n1507.xml 
035 |a (DE-627)NLM376168684 
035 |a (NLM)39129509 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Zhang, Mengyang  |e verfasserin  |4 aut 
245 1 0 |a DFT Study on the Janus ZrSSe Monolayer for Its Potential Application in NO Gas Sensing 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.08.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The growth of industry has resulted in increased global air pollution, necessitating the urgent development of highly sensitive gas detectors. In this work, the adsorption of the Janus ZrSSe monolayer for CO, CO2, NH3, NO, NO2, and O2 was studied by first-principles calculations. First, the stability of the ZrSSe monolayer is confirmed through calculations of cohesive energy and AIMD simulations. Furthermore, the calculations indicate that the Se layer exhibits higher selectivity and sensitivity toward gas molecules compared to the S layer. Specifically, among the gases adsorbed on the Se layer, NO has the shortest adsorption distance (1.804 Å), the lowest adsorption energy (-0.424 eV), and the greatest electron transfer (0.098 e). Additionally, density of states analysis reveals that adsorption of NO, NO2, and O2 on the Janus ZrSSe monolayer can induce a transition from a nonmagnetic to a magnetic state. The adsorption of NO not only alters the magnetic state but also induces a transition from a semiconductor to metal, which is highly advantageous for gas sensing applications. There results suggest that the Janus ZrSSe monolayer has the potential to serve as a highly sensitive detector for NO gas 
650 4 |a Journal Article 
700 1 |a Xia, Jianjun  |e verfasserin  |4 aut 
700 1 |a Guo, Gang  |e verfasserin  |4 aut 
700 1 |a Guo, Gencai  |e verfasserin  |4 aut 
700 1 |a Xiao, Landong  |e verfasserin  |4 aut 
700 1 |a You, Manqi  |e verfasserin  |4 aut 
700 1 |a Luo, Siwei  |e verfasserin  |4 aut 
700 1 |a Chen, Qiong  |e verfasserin  |4 aut 
700 1 |a Luo, Chaobo  |e verfasserin  |4 aut 
700 1 |a He, Chaoyu  |e verfasserin  |4 aut 
700 1 |a Tang, Chao  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 40(2024), 33 vom: 20. Aug., Seite 17348-17357  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:40  |g year:2024  |g number:33  |g day:20  |g month:08  |g pages:17348-17357 
856 4 0 |u http://dx.doi.org/10.1021/acs.langmuir.4c01480  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 40  |j 2024  |e 33  |b 20  |c 08  |h 17348-17357