Development and performance simulations of a soft X-ray and XUV split-and-delay unit at beamlines FL23/24 at FLASH2 for time-resolved two-color pump-probe experiments

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 31(2024), Pt 5 vom: 01. Sept., Seite 1168-1178
1. Verfasser: Dreimann, Matthias (VerfasserIn)
Weitere Verfasser: Wahlert, Frank, Roling, Sebastian, Treusch, Rolf, Plönjes, Elke, Zacharias, Helmut
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article XUV free-electron laser soft X-ray time-resolved pump–probe two-color experiments
Beschreibung
Zusammenfassung:open access.
The split-and-delay unit (SDU) at FLASH2 will be upgraded to enable the simultaneous operation of two temporally, spatially and spectrally separated probe beams when the free-electron laser undulators are operated in a two-color scheme. By means of suitable thin filters and an optical grating beam path a wide range of combinations of photon energies in the spectral range from 150 eV to 780 eV can be chosen. In this paper, simulations of the spectral transmission and performance parameters of the filter technique are discussed, along with a monochromator with dispersion compensation presently under construction
Beschreibung:Date Revised 05.09.2024
published: Print-Electronic
Citation Status PubMed-not-MEDLINE
ISSN:1600-5775
DOI:10.1107/S160057752400609X