Stemless reverse shoulder arthroplasty neck shaft angle influences humeral component time-zero fixation and survivorship : a cadaveric biomechanical assessment

© 2024 The Author(s).

Bibliographische Detailangaben
Veröffentlicht in:JSES international. - 2020. - 8(2024), 4 vom: 04. Juli, Seite 880-887
1. Verfasser: Cunningham, David E (VerfasserIn)
Weitere Verfasser: Habis, Ahmed A, Uddin, Fares Z N, Johnson, James A, Athwal, George S
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:JSES international
Schlagworte:Journal Article Arthroplasty Cuff tear arthropathy Implant design Implant micromotion Neck shaft angle Reverse shoulder arthroplasty Stemless
LEADER 01000caa a22002652 4500
001 NLM375232419
003 DE-627
005 20240723233633.0
007 cr uuu---uuuuu
008 240722s2024 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jseint.2024.04.001  |2 doi 
028 5 2 |a pubmed24n1479.xml 
035 |a (DE-627)NLM375232419 
035 |a (NLM)39035638 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Cunningham, David E  |e verfasserin  |4 aut 
245 1 0 |a Stemless reverse shoulder arthroplasty neck shaft angle influences humeral component time-zero fixation and survivorship  |b a cadaveric biomechanical assessment 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 23.07.2024 
500 |a published: Electronic-eCollection 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a © 2024 The Author(s). 
520 |a Background: Stemless humeral components are being clinically investigated for reverse shoulder arthroplasty (RSA) procedures. There is, however, a paucity of basic science literature on the surgical parameters that influence the success of these procedures. Therefore, this cadaveric biomechanical study evaluated the neck shaft angle (NSA) of implantation on the survivability and performance of stemless RSA humeral components during cyclical loading 
520 |a Methods: Twelve paired cadaveric humeri were implanted with stemless RSA humeral components at NSAs of 135° and 145°. Implant-bone motion at the periphery of the implant was measured with 3 optical machine vision USB3 cameras outfitted with c-mount premium lenses and quantified with ProAnalyst software. A custom 3-dimensional loading apparatus was used to cyclically apply 3 loading directions representative of physiological states at 5 progressively increasing loading magnitudes. Stemless 135° and 145° implants were compared based on the maximum implant-bone relative distraction detected, as well as the survivorship of the implants throughout the loading protocol 
520 |a Results: Primary fixation and implant biomechanical survivorship were substantially better in the 145° NSA implants. The 135° NSA implants elicited significantly higher implant-bone distractions during cyclical loading (P = .001), and implant survivorship was considerably lower in the 135° NSA specimens when compared to the 145° NSA specimens (135° NSA: 0%, 145° NSA: 50%) (P < .001) 
520 |a Conclusion: NSA is a modifiable parameter that influences time-zero implant stability, as well as the early survivorship of the stemless RSA humeral components tested in this study. NSA resections of 145° appear to promote better stability than those utilizing 135° NSAs during early postoperative eccentric loads. Further studies are required to assess if other stemless reversed humeral implant designs have improved time-zero fixation at higher NSAs 
650 4 |a Journal Article 
650 4 |a Arthroplasty 
650 4 |a Cuff tear arthropathy 
650 4 |a Implant design 
650 4 |a Implant micromotion 
650 4 |a Neck shaft angle 
650 4 |a Reverse shoulder arthroplasty 
650 4 |a Stemless 
700 1 |a Habis, Ahmed A  |e verfasserin  |4 aut 
700 1 |a Uddin, Fares Z N  |e verfasserin  |4 aut 
700 1 |a Johnson, James A  |e verfasserin  |4 aut 
700 1 |a Athwal, George S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t JSES international  |d 2020  |g 8(2024), 4 vom: 04. Juli, Seite 880-887  |w (DE-627)NLM307818438  |x 2666-6383  |7 nnns 
773 1 8 |g volume:8  |g year:2024  |g number:4  |g day:04  |g month:07  |g pages:880-887 
856 4 0 |u http://dx.doi.org/10.1016/j.jseint.2024.04.001  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_50 
912 |a GBV_ILN_65 
912 |a GBV_ILN_69 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 8  |j 2024  |e 4  |b 04  |c 07  |h 880-887