Hard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 31(2024), Pt 5 vom: 01. Sept., Seite 1346-1357
1. Verfasser: Gasilov, Sergey (VerfasserIn)
Weitere Verfasser: Webb, M Adam, Panahifar, Arash, Zhu, Ning, Marinos, Omar, Bond, Toby, Cooper, David M L, Chapman, Dean
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article hard X-rays in vivo imaging microtomography time-resolved studies
LEADER 01000caa a22002652c 4500
001 NLM374955557
003 DE-627
005 20250306101217.0
007 cr uuu---uuuuu
008 240715s2024 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577524005241  |2 doi 
028 5 2 |a pubmed25n1249.xml 
035 |a (DE-627)NLM374955557 
035 |a (NLM)39007824 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Gasilov, Sergey  |e verfasserin  |4 aut 
245 1 0 |a Hard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 03.09.2024 
500 |a Date Revised 05.09.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a open access. 
520 |a The Biomedical Imaging and Therapy facility of the Canadian Light Source comprises two beamlines, which together cover a wide X-ray energy range from 13 keV up to 140 keV. The beamlines were designed with a focus on synchrotron applications in preclinical imaging and veterinary science as well as microbeam radiation therapy. While these remain a major part of the activities of both beamlines, a number of recent upgrades have enhanced the versatility and performance of the beamlines, particularly for high-resolution microtomography experiments. As a result, the user community has been quickly expanding to include researchers in advanced materials, batteries, fuel cells, agriculture, and environmental studies. This article summarizes the beam properties, describes the endstations together with the detector pool, and presents several application cases of the various X-ray imaging techniques available to users 
650 4 |a Journal Article 
650 4 |a hard X-rays 
650 4 |a in vivo imaging 
650 4 |a microtomography 
650 4 |a time-resolved studies 
700 1 |a Webb, M Adam  |e verfasserin  |4 aut 
700 1 |a Panahifar, Arash  |e verfasserin  |4 aut 
700 1 |a Zhu, Ning  |e verfasserin  |4 aut 
700 1 |a Marinos, Omar  |e verfasserin  |4 aut 
700 1 |a Bond, Toby  |e verfasserin  |4 aut 
700 1 |a Cooper, David M L  |e verfasserin  |4 aut 
700 1 |a Chapman, Dean  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 31(2024), Pt 5 vom: 01. Sept., Seite 1346-1357  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:31  |g year:2024  |g number:Pt 5  |g day:01  |g month:09  |g pages:1346-1357 
856 4 0 |u http://dx.doi.org/10.1107/S1600577524005241  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 31  |j 2024  |e Pt 5  |b 01  |c 09  |h 1346-1357