High-throughput and high-resolution powder X-ray diffractometer consisting of six sets of 2D CdTe detectors with variable sample-to-detector distance and innovative automation system

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 31(2024), Pt 4 vom: 01. Juli, Seite 955-967
1. Verfasser: Kawaguchi, Shogo (VerfasserIn)
Weitere Verfasser: Kobayashi, Shintaro, Yamada, Hiroki, Ashitani, Hirotaka, Takemoto, Michitaka, Imai, Yasuhiko, Hatsui, Takaki, Sugimoto, Kunihisa, Sakata, Osami
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article high-energy X-rays high-throughput devices millisecond time-resolved experiments powder X-ray diffraction
LEADER 01000caa a22002652 4500
001 NLM373884370
003 DE-627
005 20240707232018.0
007 cr uuu---uuuuu
008 240620s2024 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577524003539  |2 doi 
028 5 2 |a pubmed24n1463.xml 
035 |a (DE-627)NLM373884370 
035 |a (NLM)38900456 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kawaguchi, Shogo  |e verfasserin  |4 aut 
245 1 0 |a High-throughput and high-resolution powder X-ray diffractometer consisting of six sets of 2D CdTe detectors with variable sample-to-detector distance and innovative automation system 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 07.07.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a The demand for powder X-ray diffraction analysis continues to increase in a variety of scientific fields, as the excellent beam quality of high-brightness synchrotron light sources enables the acquisition of high-quality measurement data with high intensity and angular resolution. Synchrotron powder diffraction has enabled the rapid measurement of many samples and various in situ/operando experiments in nonambient sample environments. To meet the demands for even higher throughput measurements using high-energy X-rays at SPring-8, a high-throughput and high-resolution powder diffraction system has been developed. This system is combined with six sets of two-dimensional (2D) CdTe detectors for high-energy X-rays, and various automation systems, including a system for automatic switching among large sample environmental equipment, have been developed in the third experimental hutch of the insertion device beamline BL13XU at SPring-8. In this diffractometer system, high-brilliance and high-energy X-rays ranging from 16 to 72 keV are available. The powder diffraction data measured under ambient and various nonambient conditions can be analysed using Rietveld refinement and the pair distribution function. Using the 2D CdTe detectors with variable sample-to-detector distance, three types of scan modes have been established: standard, single-step and high-resolution. A major feature is the ability to measure a whole powder pattern with millisecond resolution. Equally important, this system can measure powder diffraction data with high Q exceeding 30 Å-1 within several tens of seconds. This capability is expected to contribute significantly to new research avenues using machine learning and artificial intelligence by utilizing the large amount of data obtained from high-throughput measurements 
650 4 |a Journal Article 
650 4 |a high-energy X-rays 
650 4 |a high-throughput devices 
650 4 |a millisecond time-resolved experiments 
650 4 |a powder X-ray diffraction 
700 1 |a Kobayashi, Shintaro  |e verfasserin  |4 aut 
700 1 |a Yamada, Hiroki  |e verfasserin  |4 aut 
700 1 |a Ashitani, Hirotaka  |e verfasserin  |4 aut 
700 1 |a Takemoto, Michitaka  |e verfasserin  |4 aut 
700 1 |a Imai, Yasuhiko  |e verfasserin  |4 aut 
700 1 |a Hatsui, Takaki  |e verfasserin  |4 aut 
700 1 |a Sugimoto, Kunihisa  |e verfasserin  |4 aut 
700 1 |a Sakata, Osami  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 31(2024), Pt 4 vom: 01. Juli, Seite 955-967  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:31  |g year:2024  |g number:Pt 4  |g day:01  |g month:07  |g pages:955-967 
856 4 0 |u http://dx.doi.org/10.1107/S1600577524003539  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 