Infrared spectroscopy across scales in length and time at BESSY II

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 31(2024), Pt 3 vom: 01. Mai, Seite 613-621
1. Verfasser: Veber, Alexander (VerfasserIn)
Weitere Verfasser: Puskar, Ljiljana, Kneipp, Janina, Schade, Ulrich
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article BESSY II cellulose microfibrils infrared beamline nano-spectroscopy
LEADER 01000caa a22002652 4500
001 NLM371415039
003 DE-627
005 20240509232657.0
007 cr uuu---uuuuu
008 240424s2024 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577524002753  |2 doi 
028 5 2 |a pubmed24n1402.xml 
035 |a (DE-627)NLM371415039 
035 |a (NLM)38652580 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Veber, Alexander  |e verfasserin  |4 aut 
245 1 0 |a Infrared spectroscopy across scales in length and time at BESSY II 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 09.05.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a The infrared beamline at BESSY II storage ring was upgraded recently to extend the capabilities of infrared microscopy. The endstations available at the beamline are now facilitating improved characterization of molecules and materials at different length scales and time resolutions. Here, the current outline of the beamline is reported and an overview of the endstations available is given. In particular, the first results obtained by using a new microscope for nano-spectroscopy that was implemented are presented. The capabilities of the scattering-type near-field optical microscope (s-SNOM) are demonstrated by investigating cellulose microfibrils, representing nanoscopic objects of a hierarchical structure. It is shown that the s-SNOM coupled to the beamline allows imaging to be performed with a spatial resolution of less than 30 nm and infrared spectra to be collected from an effective volume of less than 30 nm × 30 nm × 12 nm. Potential steps for further optimization of the beamline performance are discussed 
650 4 |a Journal Article 
650 4 |a BESSY II 
650 4 |a cellulose microfibrils 
650 4 |a infrared beamline 
650 4 |a nano-spectroscopy 
700 1 |a Puskar, Ljiljana  |e verfasserin  |4 aut 
700 1 |a Kneipp, Janina  |e verfasserin  |4 aut 
700 1 |a Schade, Ulrich  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 31(2024), Pt 3 vom: 01. Mai, Seite 613-621  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:31  |g year:2024  |g number:Pt 3  |g day:01  |g month:05  |g pages:613-621 
856 4 0 |u http://dx.doi.org/10.1107/S1600577524002753  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 31  |j 2024  |e Pt 3  |b 01  |c 05  |h 613-621