Dynamic Interfacial Tension Measurement for the Kinetic Study of Eu(III) Extraction in the NaNO3/Tributyl Phosphate System Based on an Increase in Interfacial Tension

We demonstrated for the first time that interfacial tension measurements can be used to evaluate the kinetics of the solvent extraction of metal ions. The Eu(III) extraction mechanism in the nitrate ion/tributyl phosphate (TBP) system was investigated on the basis of dynamic interfacial tension. Int...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 40(2024), 16 vom: 23. Apr., Seite 8645-8653
1. Verfasser: Nishino, Kotaro (VerfasserIn)
Weitere Verfasser: Miyagawa, Akihisa, Nagatomo, Shigenori, Nakatani, Kiyoharu
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM37097316X
003 DE-627
005 20240424232207.0
007 cr uuu---uuuuu
008 240413s2024 xx |||||o 00| ||eng c
024 7 |a 10.1021/acs.langmuir.4c00410  |2 doi 
028 5 2 |a pubmed24n1385.xml 
035 |a (DE-627)NLM37097316X 
035 |a (NLM)38608006 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Nishino, Kotaro  |e verfasserin  |4 aut 
245 1 0 |a Dynamic Interfacial Tension Measurement for the Kinetic Study of Eu(III) Extraction in the NaNO3/Tributyl Phosphate System Based on an Increase in Interfacial Tension 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 23.04.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a We demonstrated for the first time that interfacial tension measurements can be used to evaluate the kinetics of the solvent extraction of metal ions. The Eu(III) extraction mechanism in the nitrate ion/tributyl phosphate (TBP) system was investigated on the basis of dynamic interfacial tension. Interestingly, the interfacial tension of the TBP droplet (γ) increased with Eu(III) extraction. This behavior can be explained by the electrocapillary effect. The time dependence of γ was kinetically analyzed, and we demonstrated that the rate-determining process was the interfacial reaction of Eu(III). Furthermore, the dependence of the mass transfer rate constant upon the concentration of the nitrate ions revealed that two nitrate ions were involved in the interfacial reaction during Eu(III) extraction. However, no change in the rate constant upon TBP concentration was observed, because the change in the TBP concentration did not affect the electrocapillary effect. We determined the forward and backward reaction rates to be k1 = (1.5 ± 0.7) × 10-6 m M-2 s-1 and k-MT = (6.9 ± 3.9) × 10-7 m s-1. Therefore, for the first time, we demonstrated that dynamic interfacial tension, which is involved in the electrocapillary effect, can be used to elucidate the kinetics of Eu(III) extraction. We expect that this study will attract the attention of researchers in several fields, including physical and analytical chemistry 
650 4 |a Journal Article 
700 1 |a Miyagawa, Akihisa  |e verfasserin  |4 aut 
700 1 |a Nagatomo, Shigenori  |e verfasserin  |4 aut 
700 1 |a Nakatani, Kiyoharu  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 40(2024), 16 vom: 23. Apr., Seite 8645-8653  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:40  |g year:2024  |g number:16  |g day:23  |g month:04  |g pages:8645-8653 
856 4 0 |u http://dx.doi.org/10.1021/acs.langmuir.4c00410  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 40  |j 2024  |e 16  |b 23  |c 04  |h 8645-8653