Hierarchical Piezoelectric Composites for Noninvasive Continuous Cardiovascular Monitoring

© 2024 Wiley‐VCH GmbH.

Bibliographische Detailangaben
Veröffentlicht in:Advanced materials (Deerfield Beach, Fla.). - 1998. - 36(2024), 26 vom: 04. Juni, Seite e2313612
1. Verfasser: Tian, Guo (VerfasserIn)
Weitere Verfasser: Deng, Weili, Yang, Tao, Zhang, Jieling, Xu, Tianpei, Xiong, Da, Lan, Boling, Wang, Shenglong, Sun, Yue, Ao, Yong, Huang, Longchao, Liu, Yang, Li, Xuelan, Jin, Long, Yang, Weiqing
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Advanced materials (Deerfield Beach, Fla.)
Schlagworte:Journal Article cardiovascular monitoring continuous monitoring of blood pressure flexible piezoelectric sensor personalized healthcare piezoelectric composite
LEADER 01000caa a22002652 4500
001 NLM370641795
003 DE-627
005 20240627232249.0
007 cr uuu---uuuuu
008 240405s2024 xx |||||o 00| ||eng c
024 7 |a 10.1002/adma.202313612  |2 doi 
028 5 2 |a pubmed24n1453.xml 
035 |a (DE-627)NLM370641795 
035 |a (NLM)38574762 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Tian, Guo  |e verfasserin  |4 aut 
245 1 0 |a Hierarchical Piezoelectric Composites for Noninvasive Continuous Cardiovascular Monitoring 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 26.06.2024 
500 |a Date Revised 26.06.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a © 2024 Wiley‐VCH GmbH. 
520 |a Continuous monitoring of blood pressure (BP) and multiparametric analysis of cardiac functions are crucial for the early diagnosis and therapy of cardiovascular diseases. However, existing monitoring approaches often suffer from bulky and intrusive apparatus, cumbersome testing procedures, and challenging data processing, hampering their applications in continuous monitoring. Here, a heterogeneously hierarchical piezoelectric composite is introduced for wearable continuous BP and cardiac function monitoring, overcoming the rigidity of ceramic and the insensitivity of polymer. By optimizing the hierarchical structure and components of the composite, the developed piezoelectric sensor delivers impressive performances, ensuring continuous and accurate monitoring of BP at Grade A level. Furthermore, the hemodynamic parameters are extracted from the detected signals, such as local pulse wave velocity, cardiac output, and stroke volume, all of which are in alignment with clinical results. Finally, the all-day tracking of cardiac function parameters validates the reliability and stability of the developed sensor, highlighting its potential for personalized healthcare systems, particularly in early diagnosis and timely intervention of cardiovascular disease 
650 4 |a Journal Article 
650 4 |a cardiovascular monitoring 
650 4 |a continuous monitoring of blood pressure 
650 4 |a flexible piezoelectric sensor 
650 4 |a personalized healthcare 
650 4 |a piezoelectric composite 
700 1 |a Deng, Weili  |e verfasserin  |4 aut 
700 1 |a Yang, Tao  |e verfasserin  |4 aut 
700 1 |a Zhang, Jieling  |e verfasserin  |4 aut 
700 1 |a Xu, Tianpei  |e verfasserin  |4 aut 
700 1 |a Xiong, Da  |e verfasserin  |4 aut 
700 1 |a Lan, Boling  |e verfasserin  |4 aut 
700 1 |a Wang, Shenglong  |e verfasserin  |4 aut 
700 1 |a Sun, Yue  |e verfasserin  |4 aut 
700 1 |a Ao, Yong  |e verfasserin  |4 aut 
700 1 |a Huang, Longchao  |e verfasserin  |4 aut 
700 1 |a Liu, Yang  |e verfasserin  |4 aut 
700 1 |a Li, Xuelan  |e verfasserin  |4 aut 
700 1 |a Jin, Long  |e verfasserin  |4 aut 
700 1 |a Yang, Weiqing  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Advanced materials (Deerfield Beach, Fla.)  |d 1998  |g 36(2024), 26 vom: 04. Juni, Seite e2313612  |w (DE-627)NLM098206397  |x 1521-4095  |7 nnns 
773 1 8 |g volume:36  |g year:2024  |g number:26  |g day:04  |g month:06  |g pages:e2313612 
856 4 0 |u http://dx.doi.org/10.1002/adma.202313612  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 36  |j 2024  |e 26  |b 04  |c 06  |h e2313612