Investigating the Utility of Near-Infrared Reflectance Imaging for Diabetic Retinopathy Screening

BACKGROUND AND OBJECTIVE: We investigated the reliability of near-infrared reflectance (NIR) imaging as a method of assessing severity of diabetic retinopathy (DR)

Bibliographische Detailangaben
Veröffentlicht in:Ophthalmic surgery, lasers & imaging retina. - 2013. - 55(2024), 6 vom: 01. Juni, Seite 318-325
1. Verfasser: Patil, Sachi A (VerfasserIn)
Weitere Verfasser: Guttha, Samyuktha P, Nair, Archana A, Pandit, Saagar, Parikh, Ravi, Lee, Ting-Fang, Hu, Jiyuan, Mehta, Nitish, Modi, Yasha S
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Ophthalmic surgery, lasers & imaging retina
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM370205375
003 DE-627
005 20240611232257.0
007 cr uuu---uuuuu
008 240328s2024 xx |||||o 00| ||eng c
024 7 |a 10.3928/23258160-20240205-02  |2 doi 
028 5 2 |a pubmed24n1437.xml 
035 |a (DE-627)NLM370205375 
035 |a (NLM)38530988 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Patil, Sachi A  |e verfasserin  |4 aut 
245 1 0 |a Investigating the Utility of Near-Infrared Reflectance Imaging for Diabetic Retinopathy Screening 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 11.06.2024 
500 |a Date Revised 11.06.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a BACKGROUND AND OBJECTIVE: We investigated the reliability of near-infrared reflectance (NIR) imaging as a method of assessing severity of diabetic retinopathy (DR) 
520 |a PATIENTS AND METHODS: One hundred ninety-five NIR images were reviewed by two graders for the number of hyporeflective foci, presence or absence of vascular abnormalities, and presumptive DR stage; these were correlated to fundus photography-defined DR stage. Interrater reliability was confirmed via one-way random effects model of intraclass correlation coefficients. Analysis of variance was used in subgroup analysis, receiver operating characteristic (ROC) curves were created to validate reliability of the model, and logistic regression was used to model foci and vascular abnormalities as predictors for moderate or worse disease 
520 |a RESULTS: A statistically significant difference in mean number of hyporeflective foci was found between no DR and moderate non-proliferative DR (NPDR; P < 0.0001), no DR and severe NPDR (P < 0.001), no DR and proliferative DR (PDR; P < 0.0001), mild and moderate NPDR (P = 0.008), mild and severe NPDR (P < 0.001), and mild NPDR and PDR (P < 0.001). The area under the ROC curve was 0.849 (CI: 0.792 to 0.905). The threshold for detection of moderate NPDR or worse was 4.75 foci, with a sensitivity of 79.0% and a false positive rate of 20.0%. Multivariate logistic regression model incorporating hyporeflective foci with vascular abnormalities (odds ratio [OR] = 1.592, 95% CI: 1.381 to 1.835; P < 0.001) was able to accurately predict moderate disease or worse, just moderate disease (OR = 1.045, 95% CI: 1.003 to 1.089; P = 0.035), severe disease (OR = 1.050, 95% CI: 1.006 to 1.096; P = 0.027), and proliferative disease (OR = 1.050, 95% CI: 1.008 to 1.095; P = 0.018) 
520 |a CONCLUSIONS: NIR imaging may be an adjunct tool in screening for DR. [Ophthalmic Surg Lasers Imaging Retina 2024;55:318-325.] 
650 4 |a Journal Article 
700 1 |a Guttha, Samyuktha P  |e verfasserin  |4 aut 
700 1 |a Nair, Archana A  |e verfasserin  |4 aut 
700 1 |a Pandit, Saagar  |e verfasserin  |4 aut 
700 1 |a Parikh, Ravi  |e verfasserin  |4 aut 
700 1 |a Lee, Ting-Fang  |e verfasserin  |4 aut 
700 1 |a Hu, Jiyuan  |e verfasserin  |4 aut 
700 1 |a Mehta, Nitish  |e verfasserin  |4 aut 
700 1 |a Modi, Yasha S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Ophthalmic surgery, lasers & imaging retina  |d 2013  |g 55(2024), 6 vom: 01. Juni, Seite 318-325  |w (DE-627)NLM224956647  |x 2325-8179  |7 nnns 
773 1 8 |g volume:55  |g year:2024  |g number:6  |g day:01  |g month:06  |g pages:318-325 
856 4 0 |u http://dx.doi.org/10.3928/23258160-20240205-02  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_24 
912 |a GBV_ILN_31 
912 |a GBV_ILN_40 
912 |a GBV_ILN_63 
912 |a GBV_ILN_65 
912 |a GBV_ILN_69 
912 |a GBV_ILN_70 
912 |a GBV_ILN_90 
912 |a GBV_ILN_91 
912 |a GBV_ILN_130 
912 |a GBV_ILN_135 
912 |a GBV_ILN_136 
912 |a GBV_ILN_151 
912 |a GBV_ILN_181 
912 |a GBV_ILN_203 
912 |a GBV_ILN_217 
912 |a GBV_ILN_235 
912 |a GBV_ILN_289 
912 |a GBV_ILN_294 
912 |a GBV_ILN_297 
912 |a GBV_ILN_350 
912 |a GBV_ILN_352 
912 |a GBV_ILN_674 
912 |a GBV_ILN_676 
912 |a GBV_ILN_688 
912 |a GBV_ILN_698 
912 |a GBV_ILN_721 
912 |a GBV_ILN_737 
912 |a GBV_ILN_791 
912 |a GBV_ILN_812 
951 |a AR 
952 |d 55  |j 2024  |e 6  |b 01  |c 06  |h 318-325