|
|
|
|
LEADER |
01000caa a22002652 4500 |
001 |
NLM368854213 |
003 |
DE-627 |
005 |
20240314235227.0 |
007 |
cr uuu---uuuuu |
008 |
240229s2024 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1111/vcp.13337
|2 doi
|
028 |
5 |
2 |
|a pubmed24n1329.xml
|
035 |
|
|
|a (DE-627)NLM368854213
|
035 |
|
|
|a (NLM)38395432
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Oikonomidis, Ioannis L
|e verfasserin
|4 aut
|
245 |
1 |
2 |
|a A comparison study between the Siemens ADVIA 120 and manual method for the differential white blood cell count in goats
|
264 |
|
1 |
|c 2024
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 14.03.2024
|
500 |
|
|
|a Date Revised 14.03.2024
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a © 2024 The Authors. Veterinary Clinical Pathology published by Wiley Periodicals LLC on behalf of American Society for Veterinary Clinical Pathology.
|
520 |
|
|
|a BACKGROUND: Although widely used, the ADVIA 120 hematology analyzer has not been previously validated for determining the differential leukocyte count in goats
|
520 |
|
|
|a OBJECTIVES: The aim of this study was to compare the differential leukocyte counts provided by the ADVIA 120 (A-diff) and the manual method (M-Diff) in goats
|
520 |
|
|
|a METHODS: EDTA blood samples that were analyzed within 4 h of collection were used in the study. The following exclusion criteria were applied: inappropriately filled tubes or tubes containing clots, erroneous ADVIA peroxidase cytograms, and blood smears of poor quality. The A-Diff was compared with the M-Diff performed by two independent observers on 200 leukocytes
|
520 |
|
|
|a RESULTS: Forty samples were included after previously excluding eight samples. The correlation between the A-Diff and M-Diff was very strong for eosinophils (r = .870, p < .001) and strong for lymphocytes (r = .796, p < .001) and neutrophils (r = .730, p < .001), while no significant correlation was observed for monocytes (r = .026, p = .872). The Passing-Bablok regression analyses revealed statistically significant constant errors for neutrophils (5.83%; 95% confidence interval [CI]: 0.41%, 12.18%) and eosinophils (1.89%; 95% CI: 1.17%, 2.71%). Bland-Altman analyses showed a statistically significant negative bias for lymphocytes (-5.0%) and a statistically significant positive bias for eosinophils (2.2%). The very low basophil percentages precluded a meaningful method comparison
|
520 |
|
|
|a CONCLUSIONS: The ADVIA 120 overall demonstrated good performance for the differential WBC count in goats under the conditions of this study. Therefore, it can be considered suitable for routine hematologic screening in goats. Nonetheless, it should be emphasized that any abnormal result should be confirmed with a blood smear evaluation
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a blood smear
|
650 |
|
4 |
|a caprine
|
650 |
|
4 |
|a complete blood count
|
650 |
|
4 |
|a hematology
|
650 |
|
4 |
|a leukocyte
|
650 |
|
4 |
|a leukogram
|
700 |
1 |
|
|a Brozos, Christos
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Tsouloufi, Theodora K
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Kiossis, Evangelos
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Kritsepi-Konstantinou, Maria
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Veterinary clinical pathology
|d 1975
|g 53(2024), 1 vom: 21. März, Seite 57-62
|w (DE-627)NLM098159984
|x 1939-165X
|7 nnns
|
773 |
1 |
8 |
|g volume:53
|g year:2024
|g number:1
|g day:21
|g month:03
|g pages:57-62
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1111/vcp.13337
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 53
|j 2024
|e 1
|b 21
|c 03
|h 57-62
|