|
|
|
|
LEADER |
01000caa a22002652 4500 |
001 |
NLM368083284 |
003 |
DE-627 |
005 |
20240503000208.0 |
007 |
cr uuu---uuuuu |
008 |
240206s2024 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.3928/23258160-20240124-01
|2 doi
|
028 |
5 |
2 |
|a pubmed24n1395.xml
|
035 |
|
|
|a (DE-627)NLM368083284
|
035 |
|
|
|a (NLM)38319059
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Choi, Hanna
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Quantitative Contrast Sensitivity Function and the Effect of Aging in Healthy Adult Eyes
|b A Normative Database
|
264 |
|
1 |
|c 2024
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 01.05.2024
|
500 |
|
|
|a Date Revised 01.05.2024
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a BACKGROUND AND OBJECTIVE: We sought to establish normative quantitative contrast sensitivity function (qCSF) values in healthy adult eyes and investigate the effect of age on qCSF
|
520 |
|
|
|a PATIENTS AND METHODS: Healthy eyes underwent qCSF testing (adaptive sensory technology) and Snellen's visual acuity (VA). Descriptive statistics and mixed-effects multivariable linear regressions were evaluated
|
520 |
|
|
|a RESULTS: A total of 334 eyes (290 patients) with median age 61 years (range 21 to 88) had qCSF values as follows: area under the log contrast sensitivity function curve: 1.18; contrast acuity: 1.32; contrast sensitivity (CS) at 1 cycle per degree (cpd): 1.32; CS at 1.5 cpd: 1.37; CS at 3 cpd: 1.38; CS at 6 cpd: 1.20; CS at 12 cpd: 0.69; CS at 18 cpd: 0.22. Linear reductions in qCSF values per decade of age ranged from -0.02 to -0.07 vs 0.01 for visual acuity (VA). Age had a greater effect on the majority of qCSF values than VA (beta standardized regression coefficient ranged from -0.309 to -0.141 for qCSF values vs 0.177 for VA)
|
520 |
|
|
|a CONCLUSIONS: We herein establish a normative database for qCSF and quantify the effect of age on qCSF values, adding evidence towards the validation of qCSF as a clinical endpoint. [Ophthalmic Surg Lasers Imaging Retina 2024;55:212-219.]
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
700 |
1 |
|
|a Vingopoulos, Filippos
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Razavi, Peyman
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Garcia, Mauricio D
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Garg, Itika
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Rodriguez, Jocelyn
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Finn, Matthew
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Baldwin, Grace
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Romano, Francesco
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Ding, Xinyi
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Bannerman, Augustine
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Tracy, Jack
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Wescott, Hannah
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Husain, Deeba
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Kim, Leo A
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Vavvas, Demetrios G
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Miller, John B
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Ophthalmic surgery, lasers & imaging retina
|d 2013
|g 55(2024), 4 vom: 01. Apr., Seite 212-219
|w (DE-627)NLM224956647
|x 2325-8179
|7 nnns
|
773 |
1 |
8 |
|g volume:55
|g year:2024
|g number:4
|g day:01
|g month:04
|g pages:212-219
|
856 |
4 |
0 |
|u http://dx.doi.org/10.3928/23258160-20240124-01
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_24
|
912 |
|
|
|a GBV_ILN_31
|
912 |
|
|
|a GBV_ILN_40
|
912 |
|
|
|a GBV_ILN_63
|
912 |
|
|
|a GBV_ILN_65
|
912 |
|
|
|a GBV_ILN_69
|
912 |
|
|
|a GBV_ILN_70
|
912 |
|
|
|a GBV_ILN_90
|
912 |
|
|
|a GBV_ILN_91
|
912 |
|
|
|a GBV_ILN_130
|
912 |
|
|
|a GBV_ILN_135
|
912 |
|
|
|a GBV_ILN_136
|
912 |
|
|
|a GBV_ILN_151
|
912 |
|
|
|a GBV_ILN_181
|
912 |
|
|
|a GBV_ILN_203
|
912 |
|
|
|a GBV_ILN_217
|
912 |
|
|
|a GBV_ILN_235
|
912 |
|
|
|a GBV_ILN_289
|
912 |
|
|
|a GBV_ILN_294
|
912 |
|
|
|a GBV_ILN_297
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_352
|
912 |
|
|
|a GBV_ILN_674
|
912 |
|
|
|a GBV_ILN_676
|
912 |
|
|
|a GBV_ILN_688
|
912 |
|
|
|a GBV_ILN_698
|
912 |
|
|
|a GBV_ILN_721
|
912 |
|
|
|a GBV_ILN_737
|
912 |
|
|
|a GBV_ILN_791
|
912 |
|
|
|a GBV_ILN_812
|
951 |
|
|
|a AR
|
952 |
|
|
|d 55
|j 2024
|e 4
|b 01
|c 04
|h 212-219
|