Regeneration of As(V)-loaded granular activated carbon through electrocoagulation

© 2024 Water Environment Federation.

Bibliographische Detailangaben
Veröffentlicht in:Water environment research : a research publication of the Water Environment Federation. - 1998. - 96(2024), 2 vom: 05. Feb., Seite e10988
1. Verfasser: Moed, Niels Michiel (VerfasserIn)
Weitere Verfasser: Ku, Young, Hsu, Ting-Hsuan
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Water environment research : a research publication of the Water Environment Federation
Schlagworte:Journal Article As(V) activated carbon electrocoagulation elution regeneration Charcoal 16291-96-6 Sodium Chloride 451W47IQ8X mehr... Arsenic N712M78A8G Water Pollutants, Chemical
Beschreibung
Zusammenfassung:© 2024 Water Environment Federation.
As(V)-loaded granular activated carbon was regenerated through electrocoagulation assisted by elution with NaCl. Adsorption of As(V) by activated carbon was highest at pH 6, and subsequent desorption in water was highest at pH 11, followed by pH 3. Lower initial pH improved arsenic removal during electrocoagulation, NaCl concentration was insignificant, but removal increased with current density. Adding Fe(II) before electrocoagulation led to an improved removal efficiency up to a concentration of 30 mg/L. Regeneration of As(V)-loaded activated carbon increased with current density and time up to a maximum of 85%. An increase in NaCl concentration to 6000 mg/L further improved regeneration to 92%. Regeneration at a lower current density only dropped slightly from 54% to 51% when doubling activated carbon concentration, demonstrating excellent scalability. Repeated adsorption-desorption tests were performed, where 81% and 69% regeneration were obtained after four regenerations with NaCl concentrations of 6000 and 750 mg/L, respectively. NaCl concentration in the tested range did not influence electrocoagulation but improved regeneration through elution. The combination of electrocoagulation and elution facilitated a higher regeneration efficiency, meanwhile removing As(V) from the solution through adsorption on iron hydroxide. PRACTITIONER POINTS: As(V)-loaded activated carbon was regenerated by electrocoagulation with elution. Regeneration increased with regeneration time and current density up to 85%. Addition of 6000 mg/L NaCl further increased regeneration to 93%. Regeneration of 82% was achieved after four regenerations. NaCl did not affect electrocoagulation but improved regeneration through elution
Beschreibung:Date Completed 07.02.2024
Date Revised 23.02.2024
published: Print
Citation Status MEDLINE
ISSN:1554-7531
DOI:10.1002/wer.10988